61 Open space prescribed for one site not to be taken for another site
(1) No building shall at any time be erected on any open space prescribed under these rules for a building and forming part of the site thereof, nor shall such open space be taken into account in determining the area of any open space required under these rules for any other building.
(2) For the purpose of this rule, the back of a building shall be deemed to be that face of the building which is furthest from any means of access to the site:
Provided that, where a building is situated at the side of more than one street or passage, the hack of the building shall be deemed to be that face of the building which is furthest from the widest of all such streets or passages:
Provided further that the Commissioner having regard to the conditions prevailing at the site and its surrounding may allow the prayer to treat some other face as the back of the building.
(3) Every building shall have exterior open spaces comprising front open space, rear open space and side open space as mentioned in rule 62 to rule 69. The minimum width prescribed for front open space, rear open space and side open spaces shall be provided along the entire front, rear and side faces of the building respectively. For this purpose, the front of the building shall be that face of the building, which faces the means of access of the building. These provisions shall also be applicable to each individual building when a plot of land contains more than one building, provided that the rear open space for this purpose is to be taken as the average width available along the entire rear face of the building with the minimum width available being not less than 50% of the stipulated width.
(4) Every open space required to be provided under these rules shall be kept open to sky and no roof, weather shed or cornice more than 0.6 m. in width shall overhang or project over the said open space.
62 Minimum open spaces with respect to buildings for residential use
| Height of building | Front open space | Open space on side-1 | Open space on side-2 | Rear open space |
|---|---|---|---|---|
| Upto 7.0 m | 1.2 m | 1.2m | 1.2 m | 2.0 m |
| Above 7.0 m upto 10.0 m | 1.2m | 1.2m | 1.2m | 3.0m |
| Above 10.0 m upto 12.5 m | 1.2m | 1.2m | 1.5m | 3.0m |
| Above 12.5 m upto 15.5 m | 2.0m | 1.5m | 2.5m | 4.0m |
| Above 15.5 m upto 20.0 m | 3.5m | 4.0m | 4.0m | 5.0m |
| Above 20.0 m upto 25.5 m | 5.0m | 5.0m | 5.0m | 6.5m |
| Above 25.5 m upto 40.0 m | 6.0m | 6.5m | 6.5m | 8.5m |
| Above 40.0 m upto 60.0 m | 8.0m | 8.0m | 8.0m | 10.0m |
| Above 60.0 m upto 80.0 m | 10.0m | 15% of the height of building or 11.0 m. whichever is less | 15% of the height of building or 11.0 m. whichever is less | 12.0m |
| Above 80.0 m | 12.0m | 15% of the height of building or 14.0 m. whichever is less | 15% of the height of building or 14.0 m. whichever is less | 14.0m |
Provided that in case of a building for residential use having irregular shape at the back of the building, the rear open space will be considered on the basis of the average rear open space as per following calculations :
(a) a minimum of 1.5 m for building height upto 7.0 m;
(b) a minimum of 2.0 m for building height above 7.0 m and upto 12.5 m;
(c) a minimum of 3.0 m for building for building height above 12.5 m and upto 15.5 m;
(d) a minimum of 4.0 m for building height above 15.5 m and upto 20.0 m.;
Explanation : Total projected area of the rear open space in sqm. should be divided by width of the rear of the building in meters.
[PART I
63 Minimum open spaces with respect to buildings for educational use
| Height of building | Front open space | Open space on side-1 | Open space on side-2 | Rear open space |
|---|---|---|---|---|
| Upto 10.0 m for land area upto 500.0 sq. m | 2.0m | 1.8 m | 4.0 m | 3.5 m |
| Upto 10.0 m for land area above 500.0 sq. m | 3.5 m | 3.5 m | 4.0 m | 4.0 m |
| Above 10.0 m upto 15.5 m | 3.5 m | 4.0 m | 4.0 m | 5.0 m |
| Above 15.5 m upto 20.0 m | 5.0 m | 5.0 m | 5.0 m | 6.0 m |
| Above 20.0 m | 20% of the height of building or 6 m, whichever is more | 20% of the height of building or 5 m, whichever is more | 20% of the height of building or 5m, whichever is more | 20% of the height of building or 8 m, whichever is more |
64 Minimum open spaces with respect to buildings for institutional, assembly, business, marcantile and mixed uses.
| Height of building | Front open space | Open space on side-1 | Open space on side-2 | Rear open space |
|---|---|---|---|---|
| Upto 10.0m for land area upto 500.0 sq. m | 2.0m | 1.2 m | 4.0 m | 4.0 m |
| Upto 10.0 m for land area above 500.0 sq. m | 3.0 m | 3.5 m | 4.0 m | 4.0 m |
| Above 10.0 m upto 20.0 M | 4.0 m | 4.0m | 4.0 m | 5.0 m |
| Above 20.0 m upto 25.5 m | 5.0 m | 5.0m | 5.0 m | 6.0m |
| Above 25.5 m upto 40.0 m | 6.0 nr | 6.5 m | 6.5 m | 9.0m |
| Above 40.0 m upto 60.0 m | 8.0 m | 9.0 m | 9.0 m | 10.0 m |
| Above 60.0 m upto 80.0 m | 10.0 m | 15% of the height of building or 11.0 m. whichever is less | 15% of the height of building or 11.0 m. whichever is less | 12.0 m |
| Above 80.0 m | 12.0 m | 15% of the height of building or 14.0 m. whichever is less | 15% of the height of building or 14.0 m. whichever is less | 14.0 m |
65 Minimum open spaces with respect to industrial and storage buildings
| Height of building | Front open space | Open space on side-1 | Open space on side-2 | Rear open space |
|---|---|---|---|---|
| Up to 10.0 m 12.5 m | 5.0 m | 4.0 m | 4.0 m | 4.5 m |
| Above 10.0 m 12.5 m upto 20.0 m | 6.0 m | 6.5 m | 6.5 m | 10.0 m |
| Above 20.0 m | 20% of the height of building or 6m, whichever is more | 20% of the height of building or 6.5m, whichever is more | 20% of the height of building or 6.5m, whichever is more | 20% of the height of building or 10.0m, whichever is more |
65A. Minimum open spaces with respect to heritage building and / or land having water body
In case of heritage building and/or land having water body, Mayor-in-Council may allow, on the recommendation of Municipal Building Committee, necessary relaxation in respect of front, sides and rear spaces keeping sufficient open space available for movement of Fire and Emergency vehicles upto the satisfaction of West Bengal Fire & Emergency Services provided that the existing Heritage Building or Water Body or both taken together occupy at least 25% of the land area.
41
66 Joint Open Space
Subject to the provisions of rules 63, 64. 65 and 66, joint open space shall be provided in between two buildings, if the height of one of such buildings exceeds 15.50 m. whether or not both buildings belong to the same owner, as follows:
(I) 7.00 m - if height of both the buildings exceeds 15.50 m;
(2) If one of the building exceeds 15.50 m. in height-
(a) 5.00 m - if height of the other building is more than 12.5 m but less than 15.5 m.
(b) 4.00 m - if height of the other building is more than 10.0 m but less than 12.5 m
(c) 3.50 m - if height of the other building is more than 7.0m but less than 10.0 m
(d) 3.00 m - if height of the other building does not exceed 7.0 m.
(3) The above rule of joint open space shall not be applicable in case the adjoining structure is not exceeding 5.0 m. in height.
(4) In case of multiple blocks of buildings connected with each other, the open spaces between the two blocks will have to be 40% 15% of the height of the lower block or 7.0 m. whichever is more.
67 Interior open space
(1) In case the whole of one side or part of at least two sides of every habitable room is not abutting the front, rear or side open spaces it shall abut an interior open space. Interior open space at ground level shall be called courtyard.
(2) Any room, which is separated only by a verandah from that interior open space, shall be deemed to abut on such interior open space for the purpose of this rule.
(3) The minimum dimension of any side of every interior open space (a) at ground level, all sides of which are enclosed by a building or part thereof, shall be 30% of the height of the building, or 3.0 m., whichever is more (b) at any other level, all sides of which are enclosed by a building or part thereof, the height shall be measured from the said level where interior open space is formed.
(4) Notwithstanding anything contained in sub-rule (3), if all sides of an interior open space are enclosed by a combination of higher and lower blocks of a building, then minimum dimension of such interior open space shall be governed by the height of lower block provided that in no case the covered "area of” such lower block shall be less than~25% of the total Covered area of the concerned building constituting the interior open space.
(5) For the purpose of this rule, if any interior open space or courtyard enclosed on three sides by a building or part there use of is meant to serve lighting and ventilation purpose to a part or whole of one side of one or more habitable rooms, then the minimum width of such open space shall be 2.4 m. for buildings upto 15.5 m. in height; 3.5 m. for buildings above 15.5 m. upto 25.5 m. in height; 5.0 m. for buildings above 25.5 m. up to 40.0 m. height; and 7.0 m. for all buildings above 40.0 m. in height.
Provided that the depth of such open space shall not exceed twice its width and the same may be reduced to 1.2 m. if no habitable room, or balcony attached to the habitable room is facing the interior open space. However, in case the depth of such interior open space is less than the width, the same shall not be considered as interior open space, but be called as "notch" and the same will be permitted without any restriction.
(6) A ventilation shaft having no access to the same except through one door for service purposes shall not be treated as a courtyard, if the area of such shaft is less than 20 sq. m.
[PART I
68 Exemption related to open space.
(a) Cornice, chajja or weather shade and all such features related to facade, treatment such as fins, flower boxes, pilasters, column capitals, arches, pediments, trellises, ducts for encasing pipe lines, pipe supports and all such features used to enhance the aesthetic quality of a building (not more than 60 cm) shall be allowed to overhang or project over open spaces Provided that such projections shall not be allowed at a height less than 2.5 m. over the ground level. Ducts for encasing pipe lines, pipe supports etc: will however be allowed from the ground level without creating obstruction to the movement of vehicles/fire tenders wherever applicable as per rule;
(b) Sewers and its appurtenances, under ground water reservoir, septic tank and ramp may be allowed to be constructed in the open spaces upto 60 cm above ground level provided that these do not obstruct vehicular movement;
(c) Notwithstanding anything contained in rule 63,64,65 the front open space is 3.50 m. or more, gate goomty not exceeding a height of 3.0 m. and an area of 9.0 sq. m. for security purposes may be allowed on the said open space. Such goomty shall be so located as not to obstruct vehicular movement from the means of access to the side or rear open spaces and shall be exempted from the provisions of rules 63, 64, 65 One such gate goomty will be allowed for every 2000 sq. m of land area;
(d) In case of residential building only, the projections (overhang) of wardrobes, alcoves, cup boards and shelves shall be permitted at floor level upto 50 cm from the first floor level and above and provided the area of each such cupboard shall not exceed 2.0 sq. m. per habitable room and shall not exceed 3% of the respective gross floor area of the building of which such cupboards form a part. However in exterior open space this can be extended to 60 cm from first floor onwards for buildings having side open space more than 2.5 m.;
(e) A canopy or canopies and or a porch/porches each not exceeding 15 sq. in. in area or one percent (1 %) of the ground floor area whichever is higher, having a clear width of not less than 2.5 m. may be allowed at a minimum clear height of 2.5 m. from the ground level provided that requisite space for the movement. of fire tenders is left all round the building unobstructed by such canopies/porches;
(f) Outdoor type transformer will be allowed to be installed in the mandatory open space provided-
(i) There will remain after such proposed installation clear minimum open space of 1.2 m. from the adjoining boundary line.
(ii) While providing such space for transformer, a minimum open space of 4.00 m. shall have To be kept to facilitate vehicular movement wherever applicable.
43