➢ Cleaning of Escalator or Travelator pit,
➢ Cleaning and lubricating all moving parts.
➢ Examining the balustrade and their attachments;
➢ Examining the safety devices.
➢ Examining and lubricating all the parts of machinery which require lubrication,
➢ Examining the worm and gear, the track, the trusses, the step treads and landings,
[PART I f these velator orm III ator or defect elator, fts; in safe and its le Lift, owner onsible ator or subject which se shall ntained illation ged by elators
PART I]
11
Examining all electrical wiring controlling devices and earthing of the entire machineries with controlling switches.
(xiii) Whenever the Lift, Escalator or Travelator, is out of order, the owner shall ensure that the machine room and all the landing gates or doors are securely locked and the users of the Lifts or Escalator or Travelators informed by a notice affixed at any conspicuous place at each floor that the Lift, Escalator or Travelator, is out of order.
(xiv) It shall not be possible to control the car from any other position and the car shall not move until all safety devises are in position;
(xv) No person shall willfully interfere with any mechanism of the Lift, Escalator or Travelator, installation.
(xvi) Whenever the Lift, Escalator or Travelator, is under maintenance, the owner shall see that indicating boards/signage to this effect are affixed in the Lift car and at every floor in case of Lift and in conspicuous positions in case of Escalator or Travelator.
-
Order for repairing the Lift, Escalator or Travelator, and prohibiting use thereof. – An order under section 11 of the Act shall be issued as early as possible in Form X and shall be served on the owner, agent or occupier of the premises or other person responsible for the working of the Lift, Escalator or Travelator, and the person on whom the order is served, shall comply with the order within the time as may be specified therein and shall report the compliance in writing to the officer by whom the order is served.
-
Authorization for erection, maintenance or erection & maintenance of Lifts or Escalator or Travelators.
- (1) No person or Firm shall be authorized to carry out erection and maintenance of Lifts or Escalator or Travelators unless such person fulfills the requirements as contained in Chapter VI.
(2) Person or Firm desirous of carrying out the work of erection and maintenance of Escalator or Travelators shall be required to obtain the certificate of registration for each purpose.
(3) The authorization granted under this Rule shall be valid for a period of 5(Five) years during which it is granted and shall be renewable for a minimum period of three years subject to a maximum of five years and subject to compliance of terms and conditions prescribed for the purpose.
- Appointment of Lift Attendant – (1) One or more Attendants, as may be necessary shall be appointed in writing by the owner of any premises to whom a Licence to Work a Lift has been granted, or by his agent, if any, for working the Lift.
(2) No person shall be eligible for appointment as a Lift Attendant unless he possesses a valid authorization certificate issued in his favour under and in accordance with the Rules contained in Chapter VI. The name of such Attendant shall be intimated to the officer authorized in this behalf by the State Government from time to time.
(3) An Inspector of Lift may relax the provision of sub-rule (I) of Rule 10 subject to such conditions as he may impose, for such period not exceeding two weeks as he thinks fit, on the ground either of emergency or special circumstances.
-
Intimation of accidents. – Where any accident occurs in the operation of any Lift, Escalator or Travelator, which results or is likely to have resulted in loss of human life or injury to any person, the owner or any agent appointed by the owner under sub Section (1) of Section 12 of the Act shall inform the Inspector immediately about the occurrence of the event of accident and a detailed report in the Form XI be submitted within 48 hours of knowledge of occurrence of accident. A written intimation of occurrence of any accident shall also be given immediately to the nearest Police Station.
-
Unused Lifts or Escalator or Travelators. – (1) Where a Lift or an Escalator or Travelator installed at any place ceases to be used, the owner or his agent, if any, shall forthwith give a written notice thereof in Form XII to surrender the license to the Chief Electrical Inspector and shall permanently block the open shaft area after disconnecting all sources of power to the lift.
(2) All gates and doors in case of such unused Lift shall be efficiently locked so as to prevent the entry of unauthorized persons to the Lift well and the owner or his agent shall, if ordered by the Inspector so to do take such other precautions as are considered necessary by the Inspector to prevent the danger from such unused Lift, Escalator or Travelator.
SI
[PART I]
- Change of name in the licence and issue to duplicate thereof. – (1) The change of name of owner of a Lift, Escalator or Travelator in the licence may be allowed on an application for the purpose to the Chief Electrical Inspector shall be accompanied by documents confirming ownership of the property, latest Tax receipt or proof of Registration of a Housing Society (having multiple Huts) registered under the Relavent Act as well as No-Objection Certificate from the previous owner(s):
(2) A duplicate licence may be issued on application made for the purpose to the Chief Electrical Inspector along with payment of fees as prescribed in Rule 14.
-
Fees for license, inspection and authorization. – All fees payable in pursuance of the provisions of the Act and these Rules for any application for license, inspection, authorization or duplicate certificate etc. shall be as per schedule of fees under this rules.
-
Conformity with the Indian Standard Specifications or equivalent International Standards. – All materials, fittings, appliances, etc. used in Lift, Escalator or Travelator and its installations shall conform to the relevant specifications of the Bureau of Indian Standard or equivalent International Standards wherever they exist and all such materials fittings, appliances, etc., used in Lift, Escalator or Travelator, shall bear thereupon appropriate BIS seal of certification. In cases of materials for which Indian Standard do not exist, the materials shall be of approved workmanship and quality. The various guidelines prescribed by the Bureau Indian Standard in this regard shall also be followed by the person to whom they are applicable.
-
Conformity with National Building Code. – The provisions of the National Building Code of India relating to the installation of the Lifts and Escalator or Travelators shall be followed.
-
Installation, operation and maintenance of Lifts or Escalator or Travelators. – Every Lift, Escalator or Travelator, shall be of sufficient mechanical strength for the purpose for which it is intended and shall be installed, protected, operated and maintained in such manner so as to prevent danger.
-
Conformity with Electricity Act. 2003, Rules and Regulations of the C.E.A. – All electrical works in connection with installation of electrical Lifts or Escalator or Travelators shall be carried out in accordance with the provisions of the Electricity Act, 2003 and the Rules or Regulations of CEA made thereunder for the time being in force.
-
Factor of safety. – The Factor of safety for any fabricated part of the Lift, Escalator or Travelator. shall not be less than five. Higher factor of safety for various other mechanical parts shall be applicable wherever specified by the Bureau of Indian Standards.
-
Instructions for rescuing passengers in a malfunctioning Lift and reviving persons suffering from electric shocks. – Instructions in Bengali .Hindi and English language for the rescue of persons from a malfunctioning Lift and reviving persons incidentally suffering from electric shock, shall be affixed by the owner or his agent in a conspicuous place in the Lift, Escalator or Travelator, machine room in which the electricity is used.
-
Initial inspection and testing of Lifts or Escalator or Travelators. – (1) Every Lift, Escalator or Travelator and its installation shall be inspected by the officer authorized in this behalf by the State Government before the grant of licence.
(2) The owner of the Lift, Escalator or Travelator, shall at an interval of every six months from the date of grant of licence under Section 6 get his Lift, Escalator or Travelator, inspected and tested by a person authorized under Section 10 of the Act and submit the report to the Chief Electrical Inspector regarding the condition of the Lift, Escalator or Travelator. An entry of such inspection report shall be made in the log book in prescribed Form VI for Lift and Form XIII for Escalator or Travelator.
(3) In the event of the failure of the owner or his agent of any Lift, Escalator or Travelator, and its installation to rectify the defects in its Lift, Escalator or Travelator and installation thereof informed by the Chief Inspector or the Inspector in Form X and within the time indicated therein, an order to discontinue the use of such Lift, Escalator or Travelator or its installation shall be issued under Section 11 after giving to the owner or his agent of 48 hours' notice in writing and such Lift. Escalator or Travelator or its installation shall not be resumed until Chief Inspector or the Inspector is satisfied that the defects having been removed and the approval in writing for the purpose is given:
Provided that use of such Lift. Escalator or Travelator or its installation shall be resumed if on an appeal made under of section 16, the appellate authority has superseded such order.
PART I]
13
(4) Notwithstanding the provisions of these Rules, the owner or his agent or occupier shall at all times be solely responsible for the maintenance of his Lift, Escalator or Travelator, installation in such condition as to be free from danger:
Provided that when it is proved that the poor maintenance is attributable to any negligence on the part of a person holding the authorization issued under Rule 9, such person shall also be held liable along with the owner.
-
Separate electrical connection. - A separate and independent electrical isolating switch with protection shall be provided exclusively for the use of Lift, Escalator or Travelator, with proper earthing as per BIS.
-
Appeals.- (1) An appeal under Section 16 of the Act from an order specified in column (2) of the table below, shall be made in writing to the State Government within the period specified in the corresponding entry in column (3) of that table and shall be accompanied by a copy of the order appealed against and a non-refundable fee as to be notified by the State Government.
THE TABLE
| SI.No. | ORDER APPEALED AGAINST | PERIOD OF LIMITATION |
|---|---|---|
| (1) | (2) | (3) |
| (a) | An order under Section 5 refusing the permission to erect a Lift | Ninety days from the date of such order. |
| (b) | An order under Section 6 refusing the grant of Licence to Work a Lift | Ninety days from the date of such order. |
| (c) | An order under Section 11 | Thirty days from the date of such order |
| (d) | An order under Section 14 suspending or cancelling the License to Work a Lift | Thirty days from the date of such order. |
(2) The non-refundable fee as prescribed shall be paid in respect of every appeal and a copy of the challans showing payment of fee shall accompany every Appeal.