In conformity with the intent and spirit of these Regulations, the Competent Authority may:-
I. decide on matters where it is alleged that there is an error in any order, requirement, decision, determination made by any officer under delegation of powers in Regulation or interpretation in the application of these Regulations;
II. interpret the provisions of these Regulations in various contexts not covered explicitly. The Competent Authority's decision will be final and binding on all concerned.
43
III. authorize the development of a building or the use of premises for public services for public utility purposes only, where he finds such an authorization to be reasonably necessary for the public convenience and welfare, even if it is not permitted in any land use classification.
In specific cases where a clearly demonstrable hardship is caused, the Competent Authority may for reasons to be recorded in writing, by special permission, permit any of the specifications / guidelines / regulations / any other specified by these Regulations to be modified, in consultation with a Technical Advisory Committee which may be established by GIFTCL.
Penalties in case of non-compliance: Any person contravening any of the GIFTCL or any of the provisions of the Development Plan shall on such contravention be liable to a punishment as provided in the Gujarat Town Planning & Urban Development Act, 1976, and Rules framed there under as in force from time to time.
Annexure
GIFT Area Development Control Regulations FORM: DP – A – 01
Application for Development Permission ¹
Application for development permission under sections 27, 34 and 49 of G.T.P. & U. D. Act. 1976.
To
The Competent Authority
Sir,
I hereby give intimation that I intend to develop the following building in GIFT Area, in accordance with the GIFT Area Development Control Regulations and UDAS provided by the GIFT:.
| Sr. No. | Details | |
|---|---|---|
| 1. | Building ID | |
| 2. | Sub Enclave Name | |
| 3. | Enclave Name |
I forward herewith the following plans and specifications in quadruplicate duly signed by me and.... (Name in block letters) the Architect/Engineer/Structural Engineer/Supervisor/Town Planner/Landscape Architect/Urban Designer, Accreditation No.....who has designed the proposed development.
| Sr. No. | Documents |
|---|---|
| 1. | True/Attested copy of Letter of Allotment as issued by the GIFT. |
| 2. | True/Attested Copy of ‘Agreement to Lease’, |
| 3. | UDAS as provided by the GIFT. |
| 4. | Key plan |
| 5. | Site plan |
| 6. | Building drawings |
| 7. | Utility Statement |
| 8. | Certificate for Undertaking of Accredited Architect/Engineer |
| 9. | Any other document as prescribed by the Competent Authority or stipulated in the Development Permission. (Please specify) |
I shall abide all the compliance of the GIFT Area Development Control Regulations and any notices through letter in sprit of these regulations. In case of any misrepresentation or by producing false documents, such development permission shall be cancelled/revoked.
I request that the Development Permission may be accorded to me.
Date:................
Signature of Developer. Name of the Developer. (in block letters) Address of Developer.
¹ Application to be made on the letterhead of the Developer
FORM: DP - A - 02
Statement Formats for Development Permission ²
- Area Calculations and use Distribution for Building
| Sr.No | Floor | Commercial Use | Residential Use | Institutional use | Services | Total in sq.m (A) | Deductions as per GIFT Area DCR 5.1.1 (B) in sq.m | Built up Area (A-B) in sq.m |
|---|---|---|---|---|---|---|---|---|
| 0 | Basement | |||||||
| 1 | Floor 1 | |||||||
| 2 | Floor 2 | |||||||
| 3 | Floor 3 | |||||||
| 4 | Floor 4 | |||||||
| n | Terrace | |||||||
| Total |
2. Utilities Statement for Building_
| BUA (SqM) | Total Water Demand | Total sewerage generation (MLD) | Total Solid waste generation (Tones) | |||||
| Fire water | Potable water | Flushing water | E- waste | Organic waste | Inert waste | Recyclable waste | ||
- Power Requirement for Building
| Power requirement | Ventillation &Cooling Load (KW) | Miscellaneous power Requirement (KW) | Total Power Requirement (KW) | |||
| Lighting load (KW/ SqM) | Power load (KW/ SqM) | Water Pumping Load (KW) | Lifts and escalators load (KW) | |||
4. DCS Requirement for Building.
² Statement Formats to be made on the letterhead of the Developer
| BUA (SqM) | HVAC requirement | Total DCS requirement (TR) | ||
| Cooling area (SqM) | Cooling volume | Ventilation volume | ||
- Parking Requirement for Building
| BUA (SqM) | Parking Required / 100 SqM of Gross BUA (Nos) (According to GIFT Plan) | Total Parking demand (Nos) | Car (%) | TW (%) | Parking required at Basement (Nos) | Parking required at MLP (Nos) |
|---|---|---|---|---|---|---|
GIFT Area Development Control Regulations FORM: DP – A – 03
Certificate of Undertaking of Accredited Architect/Engineer ³
To
The Competent Authority
Ref:
| Sr. No. | Details | |
|---|---|---|
| 1. | Building ID | |
| 2. | Sub Enclave Name | |
| 3. | Enclave Name |
For
(Name of Owner/Organiser/Developer/Builder)
Address: ____
Tel.No.:____
I am a member of Council of Architects/Engineers and I am possessing current registration to act as accredited Architect/Engineer.
I hereby certify that I am appointed as the Accredited Architect/Engineer/Surveyor to prepare the plans, sections and details as required under the provisions of the GIFT Area Development Control Regulations for the above mentioned project and that I have prepared and signed the same and that the execution of the project shall be carried out under my direction and supervision of supervisor or owner, as per the approved drawings. I am fully conversant with the provisions of the GIFT Area Development Control Regulations, which are in force, and about my duties and responsibilities under the same and I undertake to fulfill them in all respects, except under the circumstances of natural calamities.
1. Scope
These regulations are applicable to all buildings and facilities used by the public. It does not apply to private & public residences.
2. Access Path/Walk Way
Access path from the entry and surface parking to Building entrance shall be minimum of 1800 mm wide having even surface without any steps. Slope if any, shall not have gradient greater than 5%. Selection of floor material shall be made suitably to attract or to guide visual impaired persons. (Hereinafter referred to as “guiding floor material”). Finishes shall have a non‐slip surface with a texture traversable by a wheel chair. Curbs wherever provided should blend to a common level.
3. Parking
For Parking of vehicles, the following provisions shall be made
a. Parking should be within 30.00 meters of the main entrance of the building.
b. The width of parking bay shall be minimum 3.60 meters. Overall minimum dimensions shall be 3.60m X 4.80 m.
c. The parking should have the international signage (as explained in regulation no. 16) painted on the ground and also on a sign‐post/board put near it.
d. Required no of reserved parking spaces shall be as below
| Spaces in Parking Lot | Required no. of reserved parking spaces |
|---|---|
| 1-25 | 1 |
| 26-50 | 2 |
| 51-75 | 3 |
| 76-100 | 4 |
| 101 and above | 5 plus 1 per 25 above 100 |



Gujarat International Finance Tec‐City

4. Approach
Every building or block should have at least one entrance accessible to the handicapped and shall be indicated by proper signage. This entrance shall be approached through a ramp together with the stepped entry.
5. Ramp
a. Surfaces of ramp and landing shall be finished with non‐slip material to enter the building
b. Minimum width of ramp shall be 1200 mm
c. Maximum gradient of 1:12
d. Inclined stretch of a ramp shall not exceed 9m having handrails at a height of 850mm to 900mm on both sides extending 300mm beyond top and bottom of the ramp
e. Minimum gap from the adjacent wall to the handrail shall be 50mm

6. Steps and Stairs
a. Uniform risers : 150mm and treads: 300mm
b. The steps should have an unobstructed width of at least 1200mm
c. The landing should be at least 1200mm long, clear of any door swing
d. Stair edges should have bright contrasting colours : 50mm minimum
e. The maximum height of flight between landing to be 1200mm
f. Stairs should have continuous handrails on both sides, including the wall (if any) at a height of 850mm‐900mm
g. Nosing to be avoided
7. Entrance Landing
Entrance landing shall be provided adjacent to the ramp at a minimum dimension of 1800mm X 2000mm. The entrance landing that adjoin the top end of a slope shall be provided with guiding floor material. Landing shall have a non‐slip surface with a textured finish. Curbs wherever provided should land to a common level.
Gujarat International Finance Tec‐City
8. Corridors
a. Should have an unobstructed minimum width of 1500mm
b. All protruding objects more than 100mm from the wall to be placed either in a niche or above 2100 mm from the floor
c. Guiding floor material shall be provided

9. Doors
a. Minimum clear opening of the door shall be 900mm and it shall not be provided with a step that obstructs the passage of wheel chair user
b. Threshold shall not be more than 12mm
c. Door should not open into corridors
d. A distance of 450mm should be provided beyond the leading edge of the door
e. Should be fitted with lever action locks and D‐handles of circular section. Knob handles should be avoided
f. Kick places are recommended 300mm from bottom

10. Lifts
a. Wherever lift is required as per bye laws, provisions of at least one lift shall be made for the wheel chair user with the following minimum cage dimensions of
Clear internal depth: 1100mm
Clear internal width: 2000mm
Clear door width: 900mm
Gujarat International Finance Tec‐City
b. A handrail not less than 600mm long at 1000 mm above floor level shall be fixed adjacent to the control panel
c. The lift lobby shall be of an inside measurement of 1800mm X 1800mm or more
d. The time of an automatically closing door should be 5 seconds and the closing speed should not exceed 0.25m/sec
e. The interior of the cage shall be provided with a device that audibly indicates the floor the cage has reached and indicates that the door of the cage is either open or closed.
11. Toilets
One special W.C. in a set of toilet shall be provided for the use of handicapped persons with essential provision of wash basin near the entrance with proper signage.
a. The minimum size shall be 1500mm X 1800mm
b. Minimum clear opening of the door shall be 900mm and the door shall be swing out
c. Suitable arrangement of vertical/horizontal handrails with 50mm clearance from wall shall be made in the toilet
d. The top of the W.C. shall be 500mm from the floor
e. Should have slip resistant flooring
f. Wash basin shall have a knee space of at least 760mm wide by 200mm deep by 650mm – 680mm height with lever type handle
g. Shall be provided with a switch that activates an emergency alarm



12. Drinking Water
Suitable provision of drinking water shall be made for the handicapped near the special toilet provided for them.
13. Service and Information Counters
Public dealing counters and writing surfaces should not be more 800mm from the floor, with a minimum clear knee space of 650mm – 680mm height and 280mm – 300mm deep.
Gujarat International Finance Tec‐City

14. Relaxation
In the buildings meant for predominant use of children, it will be necessary to suitably alter the height of the handrails and other fittings & fixtures etc.
15. Controls
Window lever and electrical control should be maximum in the range of 450 mm to 1200 mm from the floor.
16. Explanatory Notes
i. Guiding/Warning Floor Material
The floor materials to guide or to warn the visually impaired persons with a change of colour or material with conspicuously different texture and easily distinguishable from the rest of the surrounding floor materials is called guiding or warning floor materials. The material with different texture gives audible signals with sensory warning when a person moves on this surface with walking stick. The guiding/warning floor material is meant to give the directional effect or warn a person at critical places. This floor material shall be provided in the following areas:
a. The access path to the building and to the parking area
b. The landing lobby towards the information board, reception, lifts, staircase and toilets
c. Immediately at the beginning/end of walkway where there is vehicular traffic
d. At the location abruptly changing in level or ramp
e. Immediately in front of an entrance/exit and the landing
ii. Handrails
a. Should be circular in section with a diameter of 40mm – 45mm
b. At least 45mm clear of the surface to which they are attached
c. At the height of 850mm – 900mm from the floor
d. Should extend by at least 300 mm beyond the head and foot of the flight and ramp and should be grouted to the ground
e. Should be of contrasting colour

Gujarat International Finance Tec‐City
iii. Proper Signage
Appropriate identification of specific facilities within a building for the handicapped persons should be done with the proper signage. Visually impaired persons make use of other senses such as hearing and touch to compensate for the lack of vision, whereas the visual signals benefit those with hearing disabilities.
Government of Gujarat Urban Development and Urban Housing Department Notification No.gh/v/ 19 of 2021/PRCH-132020-64-DH-L Sachivalaya, Gandhinagar.
NOTIFICATION
Dated. 91312021
THE GUJARAT TOWN PLANNING AND URBAN DEVELOPMENT ACT, 1976.
NO.GH/V/ 19 of 2021/PRCH-132020-64-DH-L: WHEREAS the Government of Gujarat has sanctioned the Development Plan along with the General Development Control Regulation of GIFT Urban Development Authority under Government Notification, Urban Development and Urban Housing Department No.GH/V/170 of 2011/GIFT-102011-2523-L, dated 19.10.2011 (hereinafter referred to as the “said Development Plan” and the “said Authority” respectively);
AND WHEREAS the Government of Gujarat was of the opinion that it was necessary, in the public interest, to make variation in the said Development Plan of the said Authority;