Access path from plot entry and surface parking to building entrance shall be minimum of 1800 mm wide having even surface without any steps. Slope, if any, shall not have gradient greater than 5%. Selection of floor materials shall be made suitably to attract or to guide visually impaired persons (Limited to coloured for material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emit different send to guide visually impaired persons hereinafter referred to as “guiding floor material” (Annexure-I). Finishes shall have a non slip surface with a texture traversable by a wheel chair. Curbs wherever provided should blend to a common level.
4.2 Parking: For parking of vehicles of handicapped people the following provisions shall be made:
a) Surface parking for two cars spaces shall be provided near entrance for the physically handicapped persons with maximum travel distance of 30.0 meter from building entrance.
b) The width of parking bay shall be minimum 3.6 meter.
c) The information stating that the space is reserved for wheel chair users shall be conspicuously displayed.
d) Guiding floor materials shall be provided or a device which guides visually impaired persons with audible signals or other devices which serves the same purpose shall be provided.
4. BUILDING REQUIREMENTS:
The specified facilities for the building for physically handicapped persons shall be as follows:
Approach to plinth level
Corridor connecting the entrance/exit for the handicapped
Stairways
Lift
Toilet
Drinking water
5.1 Approach to plinth level:- Every building should have at least one entrance accessible to the handicapped and shall be indicated by proper signage. This entrance shall be approached through a ramp together with the stepped entry.
5.1.1 Ramped Approach:- Ramp shall be finished with non slip material to enter the building. Minimum width of ramp shall be 1800 mm. with maximum gradient 1:12, length of ramp shall not exceed 9.0 meter having 800 mm high hand rail on both sides extending 300 mm beyond top and bottom of the ramp. Minimum gap from the adjacent wall to the hand rail shall be 50 mm.
5.1.2 Stepped Approach:- For stepped approach size of tread shall not be less than 300 mm and maximum riser shall be 150 mm. Provision of 800 mm high hand rail on both of the stepped approach similar to the ramped approach.
5.1.3 Exit/Entrance Door:- Minimum clear opening of the entrance door shall be 900 mm and it shall not be provided with a step that obstructs the passage of a wheel chair use. Threshold shall not be raised mort ha 12 mm.
5.1.4 Entrance Landing:- Entrance landing shall be provided adjacent to ramp with the minimum dimension 1800 mm X 2000 mm. The entrance landing that adjoin the top end of a slope shall be provided with floor materials to attract the attention of visually impaired persons (limited to coloured floor material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emit different sound to guide visually impaired persons hereinafter referred to as “guiding floor material” (Annexure-I) finishes shall have a non slip surface with a texture traversable by a wheel chair. Curbs wherever provided should bled to a common level.
5.2 Corridor connecting the entrance/exit for the handicapped:- The corridor connecting the entrance/exit for handicapped leading directly outdoors to a place where information
connecting the overall use of the specified building can be provided to visually impaired persons either by a person or by sings, shall be provided as follows:
a) Guiding floor materials, shall be provided or devices that emit sound to guide visually impaired persons.
b) The minimum width shall be 12500 mm.
c) In case there is a difference of level slope ways shall be provided with a slope of 12:12
d) Hand rails shall be provided for ramps/slope ways.
5.3 Stair ways:- One of the stair-ways near the entrance/exit for the handicapped shall have the following provisions.
a) The minimum with shall be 1350 mm.
b) Height of the riser shall not be more than 150 mm and width of the tread 300mm. The steps shall not have abrupt (Square) nosing.
c) Maximum number of risers on a flight shall be limited to 12.
d) Hand rails shall be provided on both sides and shall extend 30 mm on the top and bottom of each flight of steps.
5.4 Lifts:- Wherever lift is required as per bye-laws, provisions of at least one lift shall be made for the wheel chair user with the following cage dimensions of lift recommended for passenger lift of 13 persons capacity by Bureau of Indian Standards.
Clear internal depth 1100mm
Clear internal width 2000mm
Entrance door width 900mm
a) A hand rail not less than 600mm long at 1000mm above floor level shall be fixed adjacent to the control panel.
b) The lift lobby shall be of an inside measurement of 1800 mm X 1800 mm or more.
c) The time of an automatically closing door should be minimum 5 seconds and the closing speed should not exceed 0.25 meter/sec.
d) The interior of the cage shall be provided with a devise that audibly indicate the floor the cage has reached and indicates that the door of the cage for entrance/exit is either open or closed.
5.5 Toilets: One special W.C. in a set of toilet shall be provided for the use of handicapped with essential provision of wash basin near the entrance for the handicapped.
a) The minimum size shall be 1500 X 1750 mm.
b) Minimum clear opening of the door shall be 900 mm and the door shall saving out.
c) Suitable arrangement of vertical/horizontal handrails with 50 mm clearance from wall shall be made in the toilet.
d) The W.C. seat shall be 50 mm from the floor.
5.6 Drinking Water: Suitable provision of drinking water shall be made for handicapped near the special a toilet provided for them.
5.7 Designing for Children: In the buildings meant for the pre-dominant use of the children, it will be necessary to suitable alter the height of the handrail and other fittings and fixtures etc.
Government of Andhra Pradesh Abstract:
HYDERABAD URBAN DEVELOPMENT AUTHORITY- Regulations- Hyderabad Urban Development Authority Zoning Regulations 1981- Addition of a regulation for Conservation of Historical Buildings and areas in Hyderabad City under section 59 of Andhra Pradesh Urban Areas (Development )Act 1976- Orders -Issued.
Municipal Administration and Urban Development Department.
G.O.Ms No.542,M.A
Dated.14th Decembner,1995 Read:
From the Vice Chairman, Hyderabad Urban Development Authority, Letter No. 1841 /Plg/H/94, dt.18.8.1995.
O R D E R :
The Government hereby accord their approval to the Hyderabad Urban Development Authority for addition of a new regulation to the existing Hyderabad Urban Development Authority Zoning Regulations 1981 for the Conservation of Historical Buildings and areas in Hyderabad City with no financial commitment on Government or Hyderabad Urban Development Authority as annexed to this order.
C.arjuna RAO Principal Secretary to Government
To
The Vice Chairman, Hyderabad Urban Development Authority, Sec‟bad.
The Commissioner and Special Officer, Municipal Corporation of Hyderabad.
The Managing Director, Tourism Development Corporation, Hyderabad
The Director of Town and Country, Planning, Hyderabad
The Commissioner for Land Revenue, Hyderabad
The District Collector, Hyderabad
The District Collector, Ranga Reddy District, Hyderabad
Copy to Sri, Siddiqui
Copy to Sri. P.J.J.Raju
Copy to Sri. Scrutiny cell of Law Department
//FORWARDED BY ORDER/
SECTION OFFCIER