11.1 In all Complexes including Residential Complexes, Hotels, restaurants and Lodges, business buildings, commercial buildings, Institutional buildings like hospitals, Educational buildings like schools and colleges, multi-storied buildings/Complexes, etc and all other non-residential activities provision shall be made for parking spaces as per the following requirements:
TABLE VI
| Category of building/activity | Parking area to be provided as percentage of total built up area | Parking area to be provided as percentage of total built up area |
| Category of building/activity | In MCH Area | In Municipalities and rest of Development Authorities areas |
| Shopping Malls with Multiplexes, Multiplex Complexes, Information Technology Enabling Services Complexes | 60 % | 50 % |
| Hotels, restaurants, lodges, Cinema halls, business buildings, other commercial buildings, Kalyana Mandapams, Offices, & high-rise buildings / Complexes | 40% | 30 % |
| Residential Apartment Complexes, Hospitals, Institutional buildings, Industrial buildings, Schools, Colleges & other educational buildings | 30 % | 20 % |
| Godowns & Others | 20 % | 20 % |
11.2 The parking spaces may be provided in (for all Schemes) :
(a) basements or cellars (one or more)/multi-level (allowed for plots 750 sq m and above only); or
(b) on stilt floor or in upper parking floors (at any level)
(c) in the open space over / setbacks (except the front setback) to be left around the building with adequate vehicular access, aisle, drives, ramps required for maneuvering of vehicles, or
(d) common pool parking area (in the case of Group Housing Scheme/Residential enclave/Cluster housing/Row housing schemes) or
(e) a combination of any or all the above
11.3 The other aspects for providing parking spaces are:
(i) Common and Continuous cellar parking floors between adjoining buildings would be allowed depending upon structural safety aspects, mutual agreement between owners, etc.
(ii) The parking spaces should be efficiently designed and clearly marked and provided with adequate access, aisle, drives and ramps required for maneuvering of vehicles.
Stilt floor /Cellar parking floor shall be used only for parking and not for any habitation purpose. Misuse of the area specified for parking of vehicles for any other use shall be summarily demolished / removed by the Enforcement Authority.
For parking spaces in basements and upper storeys of parking floors, at least two ramps of minimum 3.6 m width or one ramp of minimum 5.4 m width and adequate slope shall be provided. Such ramps may be permitted in the side and rear setbacks after leaving sufficient space for movement of fire-fighting vehicles. Access to these may also be accomplished through provisions of mechanical lifts.
Basement/cellar shall be set back at least 1.5 m from the property line.
Up to 10% of cellar may be utilised for utilities and non-habitation purpose like A/C Plant room, Generator room, STP, Electrical installations, Laundry, etc,
Space over and above 6m in front setback may be considered as off-street parking space.
Visitors’ parking to be provided shall be 10 % of the area mentioned in Table VI, and may be accommodated in the mandatory setbacks other than the front setback, wherever such setbacks are more than 6m.The Visitors’ Parking facility shall be open to all visitors.
In respect of Apartment Complexes / Building / Block, in sites up to 750 sq m the Parking requirement shall be deemed to be met if the entire stilt floor is left for parking. A WC/Toilet facility shall be provided for watch and ward in the stilt floor.