(a) In case of Group Housing Schemes, of the total number of dwelling units proposed, atleast 25 % shall be EWS dwelling units and atleast 15 % shall be LIG dwelling units of the total dwelling units constructed, and the number of EWS and LIG dwelling units shall be minimum 200 so to qualify for incentives and requirements under this Affordable Housing Scheme.
(b) In case of layouts/plotted Schemes for housing, minimum 25 % of the total number of plots shall be EWS and 15 % shall be for LIG in such Affordable housing component,
and such number of plots of EWS and LIG shall be minimum 200 so to qualify for incentives and requirements under this Affordable Housing Scheme.
(c) The maximum size of plots/plinth area permissible in such schemes shall be as follows:
| Sl.No. | Category | Maximum size of plot permissible in case of plotted and similar development | Maximum size of dwelling unit permissible in case of group Housing and similar Development (excluding common areas like balcony, staircase, corridor) |
|---|---|---|---|
| 1 | EWS | 35 sq m | 35 sq m |
| 2 | LIG | 55 sq m | 48 sq m |
| 3 | MIG | 110 sq m | 80 sq m |
All the units mentioned in the above Table above would be eligible for the incentives and subsidy under this Scheme.
(i) In case of Group Housing, the public agency/developer is given freedom to build the affordable housing units in a separate block with separate access.
(ii) In case of plotted development, the minimum abutting road to the plots shall be 9 m.
(iii) For EWS unit, a multipurpose room, a kitchenette and a WC Block is recommended. Alternatively, a hall, one room and kitchenette with common WC and bath for a group of EWS units may also be allowed.
(iv) For LIG unit, a hall, a bedroom, a kitchenette and a WC Block is recommended
(v) For MIG unit, a hall, 2 bedrooms, a kitchen area and a WC Block is recommended.
(iii) Parking requirements:
The parking requirements in such Affordable housing component shall be as follows:
| Sl. No | Jurisdiction | Minimum parking requirement as percentage of built - up area | |
|---|---|---|---|
| (1) | (2) | (3) | (4) |
| 1 | InGHMC/GVMC/Vijay awada MC areas | 5 % of total built-up area proposed for EWS and LIG; 10 % of total built-up | a)The parking requirement may be met either in basement/cellar/ |
| area in case of MIG. For other categories, it shall be as per Common Building Rules | or on stilts of respective blocks or common pool parking at ground level or a combination of the above. b)Common basement parking is to be avoided. c) The minimum parking requirement given in Col. 3 is inclusive of all requirements like visitors parking, parking for nonresidential uses, etc. d) The parking for EWS and LIG is expected to be exclusively for 2-wheelers. e) The parking requirement for MIG and other categories are expected to comprise of both 2- wheelers and 4- wheelers. f) The parking distribution shall be done accordingly and shall be treated as common area that shall be under the combined ownership and management of the Association and shall not be disposed for any other | ||
| 2 | In rest of HMDA/other UDA areas/ other Municipal Corporation areas | 3 % of total built-up area proposed for EWS and LIG; 9 % of total built-up area in case of MIG. For other categories, it shall be as per Common Building Rules | or on stilts of respective blocks or common pool parking at ground level or a combination of the above. b)Common basement parking is to be avoided. c) The minimum parking requirement given in Col. 3 is inclusive of all requirements like visitors parking, parking for nonresidential uses, etc. d) The parking for EWS and LIG is expected to be exclusively for 2-wheelers. e) The parking requirement for MIG and other categories are expected to comprise of both 2- wheelers and 4- wheelers. f) The parking distribution shall be done accordingly and shall be treated as common area that shall be under the combined ownership and management of the Association and shall not be disposed for any other |
| 3 | In other non-UDA Municipalities and other areas | 2 % of total built-up area proposed for EWS and LIG; 8 % of total built-up area in case of MIG. For other categories, it shall be as per Common Building Rules | or on stilts of respective blocks or common pool parking at ground level or a combination of the above. b)Common basement parking is to be avoided. c) The minimum parking requirement given in Col. 3 is inclusive of all requirements like visitors parking, parking for nonresidential uses, etc. d) The parking for EWS and LIG is expected to be exclusively for 2-wheelers. e) The parking requirement for MIG and other categories are expected to comprise of both 2- wheelers and 4- wheelers. f) The parking distribution shall be done accordingly and shall be treated as common area that shall be under the combined ownership and management of the Association and shall not be disposed for any other purpose or body. g) Where partial area under stilt floor is provided for parking, the rest of the area can be used for dwelling area; Where partial area in cellar floor is provided for parking, the rest of the area can be utilized for non-dwelling/publicfacilities purpose. |
3. Roads and Pathways:
There is no restriction on the percentage of area to be left for under roads and pathways in such housing projects. It would depend on design efficiency of the layout and proper access to the various blocks. Access to dwelling units, particularly where motorized vehicles are not normally expected shall be by means of paved footpaths with right-of way of 6m and pathway of 2 m. The right-of-way shall be adequate to allow for the plying of emergency vehicles and also for other services like road side drains and greenery/plantation.