- Requirements of sanitary fittings for shops and commercial offices, hotels, educational occupancy, institutional medical occupancy (hospitals, staff quarters and hostels), Government and public business occupancies and offices, assembly occupancy buildings (cinema, theatre, auditorium etc.), assembly buildings (art galleries, libraries and museums), restaurants and factories shall be as shown in ANNEXURE - G (a) to (k).
CHAPTER - V
Maximum Permissible Floor Area Ratio (F.A.R.), Height Limitation, Maximum Permissible Coverage and Types of Occupancy
- Maximum permissible Floor Area Ratio (F.A.R.), height limitation, Maximum permissible coverage and types of occupancy:
(1) Maximum Permissible Floor Area Ratio (F.A.R.) shall be regulated as under:
| Type of | Maximun permissible | |
|---|---|---|
| Sl.No. | occupancy | F.A.R |
| 1 | Residential - A | 3.0 |
| 2 | Residential - B | 2.5 |
| 3 | Special Residential | 2.0 |
| 4 | Educational | 2.0 |
| 5 | Mercantile (Commercial) | 2.5 |
| 6 | Institutional (Medical) | 2.0 |
| 7 | Government or Semi-Government | 2.5 |
| 8 | Assembly | 1.5 |
| 9 | Industrial | 1.5 |
| 10 | Storage | 2.0 |
| 11 | Hazardous | 1.2 |
Provided that any floor space used for parking or plant room shall not be taken into account in calculating F.A.R.
Provided further that in the case of vertical extension/addition, F.A.R. may be relaxed on the merit of each case.
(2) Height Limitation: The height of building shall be restricted to 19m (64’4”); Provided that if an entire floor is used as a parking space, that floor shall not be taken into account while calculating height subject to the condition that the total height of the building shall not exceed 22m. In case of plots smaller than 93 sq.m the height of a building shall not exceed 12.85m (42’2") and in case of plots of size 93 to 130 sq.m the height of building shall not exceed 16m (52’6");
Provided further that staircase cover or mumty and safety installations shall not be taken into account while calculating height.
(3) Maximum permissible coverage: The maximum permissible ground coverage shall be as follows:
| Sl.No | Size of Plots (in sq.m) | Maximum Permissible Coverage (%) |
|---|---|---|
| 1 | Lass than 93 | 71 |
| 2 | 93-250 | 68 |
| 3 | 251-400 | 67 |
| 4 | 401-600 | 66 |
| 5 | 601-800 | 65 |
| 6 | 801-1000 | 60 |
| 7 | Above 1000 | 50 |
(4) Occupancy: The occupancy of any building or part thereof shall be governed by the following provisions:
The usage of plots proposed for development/re-development shall be governed by the provisions contained in the Master Plan/Zonal Plan/Layout Plan prepared for the locality, provided where no such Plan exists; the usage of plots shall be as approved by the Aizawl Municipal Council.
CHAPTER - VI
Facilities to BE Provided for Physically Challenged Persons
- Building Requirements: The following are the requirements to be provided for the physically challenged persons in public buildings:
(1) Ramp Entrance to Public Buildings: Every public building shall have at least one ramp entrance/exit accessible to physically challenged persons and it shall be indicated by proper signage.
(2) Such entrance/exit shall have a minimum width of 1 metre and a maximum gradient of 1:12. The length of ramp should not exceed 9 metres. Handrail of the height of 0.90 metre on both sides of the ramp may be provided.
Provision for ramp may be provided to connect each floor of the public building.
(3) Staircase: If a staircase can be provided for the physically challenged persons, the requirements shall be as follows:
(a) The maximum width shall be 1.350 metres.
(b) The maximum height of rise shall be 0.15 metre.
(c) The minimum width of tread shall be 0.275 metre.
(d) The maximum number of steps on each flight of staircase shall be 10.
-
Lift: Lift capable of accommodating standard wheelchair shall be provided in any public building having G + 3 floors and more.
-
Toilet: In public buildings where toilets are required to be provided, if the required number of toilet is one, that shall be of European-type. If the required number is more than one in a floor, at least one shall be European-type. The European-type toilets shall be indicated by proper signage.