30 Structural Design:
The structural design of foundations, masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall be carried out in accordance with Part VI - Structural Design, Section 1-Loads, Section 2- Foundation, Section 3-Wood, Section 4- Masonry, Section 5-Concrete, Section 6-Steel of the National Building Code of India, 2005 taking into consideration the Indian Standards as given in Annexure F.
31 Quality of Materials and Workmanship:
All materials and workmanship shall be of good quality conforming generally to the accepted standards of Public Works Department of Mizoram and the Indian Standards Specifications and Codes as included in Part V-Building Materials and Part VIII - Constructional Practices and Safety of the National Building Code of India, 2005.
32 Building Services:
The planning, design and installation of lifts and escalators shall be carried out in accordance of Part VIII - Building Services, Section 2 - Electrical Installations, Section 3-Air Conditioning and Heating, Section V - Installation of Lifts and Escalators of the National Building Code of India, 2005.
33 Plumbing Services:
The planning, design, construction and installation of water supply, drainage and sanitation and gas supply system shall be in accordance with Part IX - Plumbing Services, Section I-Water Supply, Section 2-Drainage and Sanitation and Section 3 - Gas Supply of the National Building Code of India, 2005.
A septic tank of appropriate capacity with soak pit or any other suitable sludge disposal system shall be provided for all water closets/latrines. Such provisions shall not be located within a radius of 15 metres from a water source.
A suitable rain water harvesting facility shall also be provided in all buildings.
34 Signs and Outdoor Display Structures:
(i) The display of advertising signs and building signs on buildings and land shall be in accordance with Part X-Signs and Outdoor Display Structures of the National Building Code of India, 2005.
(ii) The type, design and construction of street furniture including bus shelters shall be to the satisfaction of the Aizawl Municipal Council.
35 Fire Safety, Detection and Extinguishing Systems:
(i) The Aizawl Municipal Council while according permission shall take into consideration the Code of Practice and Standards of Requirements recommended in the National Building Code of India, 2005.
(ii) All buildings in their design and construction shall generally ensure safety of life from fire, smoke, flames and panic arising from these or similar other causes.
(iii) Fire protection and extinguishing system shall conform to accepted standards and shall be installed as recommended in the National Building Code of India, 2005.
(iv) Fixed fire fighting equipments shall be suitably located in all types of buildings except in residential buildings not more than 15m height and shall be clearly marked by illuminated signs.
36 Solar water heating system:
A suitable solar heating system in accordance with the order/ notification of the Government of Mizoram shall be installed in all buildings as specified by the Government which are as follows:
-
Hospitals and Nursing Home
-
Guest Houses
-
Tourist Lodges
-
Bungalows
-
Schools, Colleges, Training Centres.
-
Barracks of Armed Forces and Police
-
Functional Buildings of Airports like Waiting Rooms, Rest Rooms, Catering Units.
-
Community Centres
-
All Government Buildings which are in need of hot water.
The detailed specifications, capacity etc. of the system to be installed shall be determined in the light of the guidelines issued by the Government of India.
37 Discharge of rain and waste water:
(i) If, in the interest of public safety, it is necessary to discharge rain and waste water of a building through the land of another person, the owner of such land/plot shall allow construction of a closed conduit in his land for discharging rain and waste water. If any damage, including excavation of earth, is caused to the property of the owner of the land through which the closed conduit is constructed, it shall be the responsibility of the person who constructs the closed conduit to repair/ replace the damaged property and restore it to its original condition.
If inspection and repair of the closed conduit is necessary, the owner of the land shall allow such inspection and repair as may be necessary. If there is any dispute, the decision of the officer of the Aizawl Municipal Council designated for the purpose shall be final.
(ii) Cement concrete or stone/brick masonry surface drain/closed conduit of adequate capacity to the nearest public drain shall be provided for proper disposal of surface and waste water.
(iii) Any buildings having covered area of 500sq.m or minimum discharge of 1000 lts. and above per day shall incorporate waste water recycling system. The recycled water should be used for non-drinking purposes.