10.1 Such developments shall be considered where the site is developed together with building constructions and all amenities and facilities and not disposed as open plots.
10.2 All Group Development Schemes, Group Housing Scheme / Cluster Housing Scheme applications shall in addition to the requirements under these Rules, be accompanied by:
10.3
a) A Services and Utilities Plan as per standards for water supply system, drainage and storm water disposal system, sewerage system , rain water harvesting structures, and for other utilities.
b) A landscaping plan including rain water harvesting/ water recycling details.
c) Parking & internal Circulation Plan along with Common pool parking area plan, if any.
The above shall be drawn on suitable scale with relevant details.
The minimum plot size for Group Housing Schemes and Group development Schemes shall be 4000 sq m and the minimum abutting road width shall be 12.2 m wide and black topped.
10.4 In case of housing in large plots or blocks, the proposals should be promoted with the immediate improvement of the accessibility of the site from the nearest main road by way of an approved Road Development Plan by the competent authority with a minimum width of 12.2 m which should be implemented by the licenced developer within a period of three years. Any road widening required shall be deemed to be approved under these Rules and has to be adhered to by the owners / local body / licenced developer.
10.5 All Group Housing Schemes/ Group Development Schemes/ Cluster housing / Residential Enclaves and row type development schemes shall be developed with complete infrastructure facilities and amenities as stated at (a) and (b) above.
10.6 These shall not be applicable in case of Government sponsored Housing Scheme/ approved NGOs or private schemes, and the guidelines and requirements as given in the National Building Code for Low Cost Housing / Government orders shall be followed.
10.7 Group Development Schemes & Group Housing Schemes
Group Housing Schemes are reckoned as Apartment blocks in two or more blocks. These could be high-rise or simple walk-up units. Group Development Schemes are reckoned as Building in two or more blocks in a campus or site, and could be normal height buildings or high-rise blocks or combination of both.
(a) The open spaces/setbacks for such type of development shall be as follows:
TABLE V
| Height of building block | Distance to be maintained from periphery to building block | Distance between two blocks |
| Up to 10 m* | 3 m | 2 m |
| Above 10 m & up to 15 m* | 4 m | 3 m |
| 15m & upto 18 m** | 5 m | 4 m |
| Above 18 m | As per alround setbacks required under High-rise buildings given in Table IV | |
* Stilt floor permissible and is exclusive of height of building up to 15 m. Height of stilt floor shall not exceed 2.5 m
** Only Cellars excluded from height of Building
b) Common amenities and facilities like shopping center, community hall or center / club house etc. are required to be provided in up to 5 % of the area and shall be planned and developed in cases where the units are above 50 in number and not be part of the residential blocks.
c) A through public access road of 9 m width with 2-lane black-topped is to be developed on any one side at the periphery/ as per suitability and feasibility for the convenience of accessibility of other sites and lands located in the interior.
d) In case of blocks up to 12 m height, access through pathways of 6m width branching out from the internal roads/loop road would be allowed. All internal roads and pathways shall be developed as per standards.
e) Minimum of 10 % of site area shall be earmarked for organised open space and be utilised as greenery, tot lot or soft landscaping, etc. and shall be provided over and above the mandatory open spaces. This space may be in one or more pockets.
10.8 ROW Type Housing / ROW Type Shopping Precincts:
a) Minimum site area : 1000 sq m
b) Minimum size of individual plots for row houses / Row shops: 50 sq m.
Not more than 8 plots shall be developed in a row.
Separation between two blocks shall not be less than 6 mt, which may be an open space or an alley/pedestrian plaza.
Only internal staircase would be allowed.
c) Minimum width of internal roads: 9 m ;
Internal cul-de-sac road 6m with max. length 50 mt. is allowed
d) Minimum open space : 10 % of site area
e) Height permissible: 2 floors or 6 m for plots up to 125 sq m
Stilt + 2 floors for plots above 125 sq m for row houses
f) Minimum setbacks: Front 3m ; Rear 1.5 m
The setbacks in a row can be interchangeable.
In case of row type shopping precincts, back to back shops with above front setback of 3m would be allowed.
g) In case of very large projects more than 5 acres, common amenities and facilities like shopping center, community hall/club house etc. are required to be provided in 5 % of the area.
h) In case of Row Type Shopping Precincts, common basement parking in one or more levels would be permissible subject to conditions mentioned in Rule (11).
10.9 Cluster Housing
(a) Minimum site area: 1000 sq m
(b) Minimum plot size for cluster house: 25 sq m with maximum number of 20 houses in a cluster
(c) Minimum size of cluster open space: 36 sq m with a minimum width of 6m
(d) Height permissible: 2 floors or 6 m
(e) Minimum access road to the Cluster Housing Complex: 9 m
Internal access may be through pedestrian paths of 6 m
(f) Minimum space between two clusters: 6m which may be utilised as pathway/alley
(g) Building setbacks: No setbacks are needed for interior clusters as the lighting and ventilation is either from the central open space of cluster and the surrounding pedestrian pathway/ access road of the cluster. However, interior courtyards may be provided for larger plots and building areas to facilitate lighting and ventilation. For end clusters sides that are abutting peripheral thoroughfare roads, setback shall be as per the Building line given in Table III.
10.10 Residential Enclaves:
(a) These would be allowed as gated development that are exclusive housing areas with common compound wall with access control through gates and having their own facilities and amenities. The housing units may comprise of row houses, semi-detached, detached or Apartment blocks or a mix or combination of the above. The building requirements would be as per the given type of housing.
(b) Residential enclaves would be permitted only in those sites that give through access of minimum 9 m peripheral road for the neighbouring plots or lands that are located in the interior. They would be governed by good design standards and not impinging on the overall accessibility and circulation network of the area.
(c) Minimum size of site: 4000 sq m.
(d) Size of plots and height permissible: as per type of housing and requirements as given above for the respective type of housing.
(e) Minimum Common Open space : 10 % of site area.
(f) Building setbacks: As per type of housing & requirements given above for the said type of housing and as per Table III.
(g) Internal Road requirements:
9.0 to 18 m for main internal approach roads;
9 m for other internal roads and
8 m for cul-de-sacs roads between 50-100 m length
9 m for looped roads