These Bye-laws shall be called the Port Blair Municipal Council Building Bye-Laws. (2) They shall come into force with immediate effect.
-
DEFINITION:
In these bye-Laws unless the context otherwise requires :
2.1 A person is said to erect or re-erect a building who makes any material alteration or enlargement of a building or any part thereof.
EXPLANATION: Any alteration in a building shall be deemed to be material, if it: -
(a) Affects or is likely to effect prejudicially the stability or safety of the building or the condition of the building in respect of drainage, ventilations, sanitation or hygiene, or
(b) Increase of diminishes the height or cubical capacity of, or the area covered, by the building or reduces the cubical capacity or any room in the building below the minimum prescribed in any Bye-Law; or
(c) Converts into a place for human habitation a building originally constructed for other purposes, or
(d) Involves the addition of any rooms, out-houses or other structures to any building, or
(e) Involves the construction; in a wall adjoining any land not belonging to the owner of the wall, or a door opening on to such land, or.
(f) Is in alteration f any kind which has been declared by any bye-law to be a material alternation.
2.2. ‘Appendix’ means and appendix to these bye-laws.
2.3 “Approved means approved by the authority having jurisdiction.
2.3 (a)” Authority having jurisdiction” means the Port Blair Municipal Council for the purpose of administering the Bye-Laws or any part thereof, any Committee or an official authorized by the Port Blair Municipal Council to act on its behalf herein after called the authority.
2.4 “Balcony” means a horizontal projection including a handrail, balustrade or parapet to serve as a passage or sitting our place, if roofed becomes balcony varandah.
2.5 “Basement storey” o “Cellar” means any storey of a building which is under the first storey and any portion of which below the level of the adjoining pavement of the surrounding round.
2.6 “Building” means any structure for what-ever purpose and of what so ever materials constructed and every part there-of whether used as human habitation or not and including foundation, plinth, walls, roofs, plumbing and building services, fixed platforms, verandahs, cornice, Projection, part of the building or anything affixed there- to, stair-case , door steps attached to or any wall enclosing or intended to enclosed and any land or space and signs and outdoor display structures, monuments memorials well or any contivence of permanent nature/stability built under of over ground or any existing building or construction of the ground which is to be the site or compound of a projected building.
2.6 (a) “Registered Architect/Registered Engineer/Licenced Supervisor “means an Architect’ Engineer or Licenced Supervisor in the jurisdiction of the Port Blair Municipal Council having the qualification as mentioned in these bye-law 3.5 (1) to 3.5 (iii) and registered with the Port Blair Municipal Council.
Note: The Chairperson of Prot Blair, Municipal Council with the approval of the Council shall issue licence to the persons on request, having qualification as mentioned in Bye-Laws 3.5 (i) to 3.5 (iii) for designing and supervising very building works for which permission is sought under the Bye- laws.
2.7 “Building height of “means the vertical distance measured. in the case of flat roofs from the average level of the centre line of the adjointing street to highest points of the building adjacent to the street wall, and in the case of pitched roofs up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof and in case of gabel facing the road, the mid point between the eaves level and the ridges Architectural feature serving no other function except that of decoration shall be excluded for the purpose of taking height’s and if the building does not about on a street the height shall be measured above the average level of the ground around and contiguous to the building.
2.8 “Building Line” means the line up to which the plinth of a building adjoining a street, or an extension of street or on a future street may lawfully extend
and include the line prescribed, if any. In any scheme, provided that the space between the building line and the street alignment, the following structures only are allowed.
(a) A Plinth, slope and other similar structure not being above the lower or level of the building.
(b) A fence not exceeding 1.5M in height.
(c) Any Chajja, Balcony canopy, eaves or other similar projecting portion of the building above a height of 2.75Mtrs. Measured from ground level, if no pillar wall or other structure is erected in the open space for support.
(d) CARPET AREA - The covered area of the usable rooms at any floor level (excluding the area of the wall)
2.9 “Ceiling Height” means the vertical distance between the floor and the ceiling.
2.10 “Chajja” or the Sunshade means a sloping or horizontal structural overhang usually provided over openings on external walls to provide protection from sun and rain not exceeding 60 cms.
2.11 “Chimney” means an upright shaft containing and encasing one or more flues.
2.12 “Cornice” means a horizontal ornamental projection on roof level protecting not more than 60cms.
2.13 “Courtyard” means a space open to the sky, enclosed or partially enclosed by building, Boundary walls or railing and may be at ground floor level or any other level within or adjacent to a building.
2.14 “Covered area”-ground area covered by the building immediately above plinth level, but does not include the space covered by:-
(a) Garden, rockery, well and well structures, plant nursery, water pool, swimming pool(if covered) platform round the tree, tank, foundations, bench, chabutra with open top unenclosed sides by walls and the like.
(b) Drainage, culvert, conduit, catch pit, gullypi, chamber, gutter and the like, and
(c) Compound wall, gate unstoreyed porch and portico, slide, swing, uncovered staircases, ramps, areas covered by chajja and the like.
(d) Watchman’s booth, pump house, garbage shaft, electric cabin or substations, and such other utility structures meant for the services of the building under consideration.
2.15 Cross-wall means an internal wall, built into an external wall of which it forms the limiting factor for the purpose for deciding its thickness.
2.16 Conversion means the change of occupancy or premises to an occupancy or use requiring additional occupancy permit.
2.17 Damp proof means a course consisting of some appropriate water proofing material provided to prevent penetration of dampness or moisture from any part of the structure to any part of a height of not less than 150mm above the surface of the adjoining ground.
2.18 “Detached building” means a building where walls and roof are independent of any other building- A building detached on all sides.
2.19 Drainage” means act, process, method or means of drainage, mode of discharge water, the system of drains.
2.20 DWELLING/UNIT TENEMENT- An independent housing unit with separate facilities for living, cooking and sanitary requirements.
2.21 “Existing Building” or “use” means a building structure or its use as sanctioned, approved, regularized by the competent authority, existing before the commencement of these bye-laws.
2.22 “External air” or “open air space” means space open to sky.
2.23 “External Walls” means an outer wall of a building not being partition wall, even though adjoining to a wall of another building and also a wall abutting on an interior open space of a building.
2.24 More resisting material” includes any of the following materials and things namely:-
(a) Brick work constructed of good, hard, sound, well burnt brick, fire brick, stone and other hard and incombustible material, properly bonded and solidly put together with mortar well composed of not less than one part of good fresh burnt lime and not more than two parts of clean sharp sand or with good cement mixed with sand;
(b) Iron and steel encased in cement concrete or asbestos sheet;
(c) Slate, ties, brick and terra cotta when used for covering or corbels;
(d) Flagstones when used for floors, over arches, but not exposed on the under sides and not supported at the end only;
(e) Concrete not less than 100mm in thickness, composed of broken bricks stone chipping or ballast and lime, cement or calciness gypsum when used for filling in between joint of floors.
(f) Reinforced cement concrete and other incombustible cement products; and
(g) Any article made of asbestos and cement.
2.25 FLOOR - The lower surface in a storey on which one normally walks in a building. The general term ‘Floor’ unless specifically mentioned otherwise shall not refer to a “mezzanine floor”.
2.26 Floor area ratio of F.A.R” means the quotient obtained by dividing the multiple of the total of the covered area on all floors and 100 by the area of the plot i.e.