(a) to erect a Lift or an Escalator in such place; or
(b) to make additions or alterations to existing Lift or Escalator, shall make an application in Form “A” to the Inspector. Every such application shall be accompanied by one set of drawings duly signed by the applicant showing the following particulars, namely:-
(i) Layout of the lift or escalator erection;
(ii) Plan;
(iii) Sectional elevation;
(iv) Arrangement of car and landing doors for lifts;
(v) Lift well enclosures;
(vi) Size and position of the machine relating to the lift well;
(vii) Position of hoisting machine for the lift or escalator;
(viii) Number of floors to be served and total travel by the lift;
(ix) Wiring diagram of the complete electrical installations with all wiring, light points, switch-fuses, control panels and other electrical apparatus, size of wires, earthing scheme with size of earth leads, method of construction of earth electrodes, laying of cables for lift or escalator equipment duly signed by the manufacturer of lift or escalator or company of Electrical and Mechanical Engineers to whom the lift or escalator erection work is entrusted and also signed by the licensed electrical contractor to whom the electrical erection work is entrusted;
(x) Angle of inclination for an escalator;
(xi) Type of balustrading in an escalator;
(xii) The width between balustrades in an escalator;
(xiii) Details of handrails, step treads, landing, comb plates, trusses or girders and step wheel tracks in escalator;
(xiv) The rated load in kilograms on escalator;
(xv) The factor of safety based on the static loads in the lift or escalator;
(xvi) The additions or alterations proposed to be made in existing Lift or Escalator installation shall be shown by distinct colour;
(xvii) Copy of approval obtained from the Urban Local Body concerned for the Building Plan;
(xviii) A chalan remitted into Government Treasury or by means of electronic payment through the website https://www.tnei.tn.gov.in for a fee of, -
(a) Rs.2,500/- (Rupees Two Thousand and Five Hundred only) in case of lift having 5 landings;
(b) Rs.5,000/- (Rupees Five Thousand only) in case of lift having more than 5 landings;
(c) Rs.10,000/- (Rupees Ten Thousand only) for each Escalator.
(xix) Structural Stability Certificate obtained from the registered Structural Engineer for the buildings which are constructed before the formation of Urban Local Body where additions or alterations are proposed to be made in the existing lift or escalator installations or where new Lifts or escalators are proposed to be erected in those buildings.
On receipt of an application under sub-rule(1), the Inspector shall, after making such inquiries and requiring, the applicant to furnish such additional information in Form “A” either grant permission in Form ‘’B” or refuse the permission applied for, within one month from the date of receipt of the application.”
- Licence for working a Lift or an Escalator,-
(1) Every owner of a place who is permitted to erect a Lift or an Escalator in such place under rule 3 shall, on completion of such erection of Lift or Escalator, shall give a notice to the Inspector and shall make an application to him for a licence. The notice of completion of the erection of Lift or Escalator and the application for licence shall be in Form “C” along with the following enclosures,-
(a) a work completion report of the erection of Lift or Escalator in Form “D” as obtained either from the manufacturer of Lifts or Escalators or a Company of Electrical and Mechanical Engineers, as the case may be;
(b) a completion report in Form “E” from the licensed electrical contractor;
(c) A chalan remitted into Government Treasury or by means of electronic payment through the website https://www.tnei.tn.gov.in for a fee of. –
(i) Rs.5,000/-(Rupees Five Thousand only) in case of lift having 5 landings;
(ii) Rs.10,000/-(Rupees Ten Thousand only) in case of lift having more than 5 landings;
(iii) Rs.10,000/- (Rupees Ten Thousand only) for each Escalator.
(d) Copy of insurance policy taken by the owner of the Lift or Escalator, covering insurance for the persons using such lift or escalator;
(2) On receipt of an application under sub-rule (1), the Inspector shall arrange for inspection of the Lift or Escalator within fifteen days and on getting himself satisfied that all the requirements of the Act and these rules are complied with, he may grant licence in Form “F” within fifteen days from the date of receipt of compliance report of rectification of defects, if any.
- Renewal of Licence.- (1)(a) An application for renewal of licence to work a Lift or an Escalator shall be made in Form “G’’ to the Inspector three months prior to the date of expiry of the licence along with a challan remitted into Government Treasury or by means of electronic payment through the website https://www.tnei.tn.gov.in for a fee of,-
(i) Rs.5,000/- (Rupees Five Thousand Only) in case of lift having 5 landings;
(ii) Rs.10,000/- (Rupees Ten Thousand Only) in case of lift having more than 5 landings;
(iii) Rs.10,000/- (Rupees Ten Thousand Only) for each Escalator.
(b) if the application for renewal of licence along with fee, copy of Annual Maintenance Contract executed between the owner of the lift or an escalator and the lift/escalator company, test reports obtained from the authorized
competent person for each year after the issue or renewal of licence, the Structural Stability Certificate obtained from the registered Structural Engineer for the buildings which are constructed before the formation of Urban Local Body (if applicable) and copy of renewed Insurance Policy taken by the owner of the lift or escalator covering insurance for the persons using the lift or an escalator is not produced to the Inspector within the period referred to in clause (a), an additional fee of Rs.500/- (Rupees Five hundred only), for each lift or escalator for a delay of each month or a fraction thereof, shall also be remitted into the Government Treasury or by means of electronic payment through the website https://www.tnei.tn.gov.in by the licensee.
(c) On receipt of an application with the required fee under sub-rule (1), the Inspector shall make an inspection within fifteen days and on getting himself satisfied that the provisions of the Act and these rules are complied with, the Inspector shall renew the licence in Form “F” within fifteen days from the date of receipt of rectification of defects, if any.
-
Application for licence in case of existing escalator.- Every owner of a place in which an escalator has been erected and is being worked immediately before the coming into force of the Act and is in operation, shall apply in Form “H” along with a fee of Rs.20,000/-(Rupees Twenty Thousand only) remitted into a Government Treasury or electronic mode of payment, test reports obtained from the authorised competent person, Structural Stability Certificate obtained from the registered Structural Engineer for the building where escalator is installed and a copy of Insurance policy for the persons using such an escalator and obtain a licence in Form “F”.
-
Terms and conditions of licence for working of lift or escalator.- Every lift or escalator shall be operated, subject to the following terms and conditions, namely,-
(1) The licensee shall forthwith report to the Inspector on any defect in the operation of lift or escalator;
(2) The licensee shall not carry out any additions or alterations to a lift or an escalator erected without obtaining permission in that behalf from the Inspector as required under these rules;
(3) The licensee shall not use the lift or escalator which is not in a safe condition and shall be solely responsible for the safe maintenance of lift or an escalator, so that these rules are always complied with;
(4) The maintenance of the lift or an escalator shall be done by a manufacturer of lifts or escalators or company of Electrical and Mechanical Engineers approved by the Inspector;
(5) The licensee shall produce test reports obtained from the competent person authorised under rule 14 for the lift or escalator installation at the end of every year from the date of grant or renewal of licence;
(6) No other person shall wilfully interfere with any mechanism of the lift or escalator;
(7) Every lift or escalator operator, if appointed in case of manually operated lift or escalator, must have attained the age of eighteen years and shall be a person who has been trained in the correct operation of the lift or escalator;
(8) When a lift or escalator erected at any place ceases to be used as such, the owner shall either remove it or maintain it in safe mechanical condition after disconnecting it entirely from the electric supply; all gates and doors shall be securely locked, so as to prevent the accidental entry to lift well or escalator and to prevent inadvertent use;
(9) All electrical works in connection with erection of lift or escalator shall be carried out in accordance with the provisions of the Electricity Act, 2003 (Central Act 36 of 2003) and the rules made there under and the Central Electricity Authority (Measures Relating to Safety and Electric Supply) regulations, 2010;
(10) All apparatus and components of lifts or escalators shall be of sufficient ratings and of sufficient mechanical strength for the duty which they may be required to perform under the environmental conditions of installation and shall be constructed, installed, protected, worked and maintained to ensure safety of human beings and property;
(11) The code of practices prescribed by the Bureau of Indian Standards including National Electrical Code shall be followed in respect of the lift or an escalator and their installation and wherever relevant specification of Bureau of Indian Standard does not exist, they shall conform to the relevant International Standards;
(12) The material and apparatus used shall conform to the prescribed specifications of Bureau of Indian Standards and wherever relevant specification of Bureau of Indian Standard does not exist, they shall conform to the relevant International Standards; and
(13) The lift or escalator shall be tested in the manner specified in specifications and Codes of Bureau of Indian Standards and wherever relevant specification of Bureau of Indian Standard does not exists, they shall conform to the relevant International Standards;”