| | 1.13.1 | Front _ Metres _ direction | Front _ Metres _ direction | Front _ Metres _ direction | Front _ Metres _ direction | Front _ Metres _ direction | Front _ Metres _ direction |
| | 1.13.2 | Side1 _ Metres _ direction | Side1 _ Metres _ direction | Side1 _ Metres _ direction | Side1 _ Metres _ direction | Side1 _ Metres _ direction | Side1 _ Metres _ direction |
| | 1.13.3 | Side2 _ Metres _ direction | Side2 _ Metres _ direction | Side2 _ Metres _ direction | Side2 _ Metres _ direction | Side2 _ Metres _ direction | Side2 _ Metres _ direction |
| | 1.13.4 | Rear _ Metres _ direction | Rear _ Metres _ direction | Rear _ Metres _ direction | Rear _ Metres _ direction | Rear _ Metres _ direction | Rear _ Metres _ direction |
| | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. | Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs. |
| *1.14 | Block Details | | | | | | |
| | *1.14.1 | Number of floors _Number of Basements _Number of Stilts /Ground floor _ | Number of floors _Number of Basements _Number of Stilts /Ground floor _ | Number of floors _Number of Basements _Number of Stilts /Ground floor _ | Number of floors _Number of Basements _Number of Stilts /Ground floor _ | Number of floors _Number of Basements _Number of Stilts /Ground floor _ | Number of floors _Number of Basements _Number of Stilts /Ground floor _ |
| | *1.14.2.1 | Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _ | Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _ | Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _ | Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _ | Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _ | Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _ |
| | 1.14.2.2 | Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC) | Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC) | Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC) | Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC) | Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC) | Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC) |
| | 1.14.3 | Floor | Area in Sq. Mtrs. | Classification of Occupancy: | No. Of Occupants as declared by the Builder: | No. Of occupants based on Table 20 i.e floor area divided by occupant load: | Total Aggregate width of Stair-Case in Mtrs. (as declared by the Builder): |
| | 1.14.3 | Basement -1 | | | | | |
| | 1.14.3 | Basement -2 Stilt 1/ Ground Floor | | | | | |
| | | Stilt 2 | | | | | |
| | | Floor1 | | | | | |
| | | Floor2 | | | | | |
| | | Floor3 | | | | | |
| | | Floor4 | | | | | |
| | | Floor5 | | | | | |
| | | Floor6 | | | | | |
| | | Floor7 | | | | | |
| | | Floor8 | | | | | |
| | | Floor9 | | | | | |
| | | Floor10 | | | | | |
| 1.15 | Refuge area: | Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs | Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs | Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs | Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs | Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs | Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs |
| *1.16 | Width of the road to which the building abuts and whether it is hard surfaced and motorable: | The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2 | The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2 | The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2 | The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2 | The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2 | The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2 |
| *1.17 | Entrances (Minimum width should be 4.5 mtrs. and head room clearance should be minimum 5.0 mtrs.) | Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs. | Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs. | Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs. | Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs. | Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs. | Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs. |
| *1.18 | Car parking | Car Parking Details: Basement/Stilt/Ground Floor No Of Cars | Car Parking Details: Basement/Stilt/Ground Floor No Of Cars | Car Parking Details: Basement/Stilt/Ground Floor No Of Cars | Car Parking Details: Basement/Stilt/Ground Floor No Of Cars | Car Parking Details: Basement/Stilt/Ground Floor No Of Cars | Car Parking Details: Basement/Stilt/Ground Floor No Of Cars |