(IV) Category of Buildings/Material/Trades coming under
Licence fee of Rs. 5,000/-
SI.No.
Description of Hazard
(1)
(2)
1.
Multi-Speciality, Super Speciality Hospitals/Nursing Homes and Corporate Hospitals
2.
All Star Category Hotels
3.
All Large and Medium Scale Industries/Factories registered under Factories Act, 1948
4.
Distilleries & Breweries
5.
Power Generating Industries
6.
Underground shopping centers
7.
Petroleum Refineries
8.
I-MAX and Multiplex Theatres
Form-1
(See Rule 3)
Telangana Fire and Emergency Operational Services Certificate of Appointment
(Affix
Photograph here)
This is to certify that Sri ..............has been appointed as a member of Telangana Fire Services in the rank of.................on..............underthe Act and is vested with the powers, functions and privileges of a member of service as given in the Telangana Fire Service Act and Rules.
Form - 2
III) Category of Buildings/Material/Trades coming under Licence fee of Rs. 2,500/-
SI.No.
Description of Hazard
(1)
(2)
1.
All stadiums (Indoor and Outdoor) and concert Halls
2.
Cold Storages
3.
Film Studio, Film Storage Hazard, Film Laboratory Colouring rooms and Film distribution companies
4.
Fire crackers manufacturers and storage/sales outlets (Permanent licence holders)
5.
Cement Manufacturers
6.
Coach Builders
7.
Ship Builders
8.
Ship Handlers
9.
Garments & Textile Manufacturers
Major Automobile show rooms & Authorized Service Centers (Four Wheelers)
All Residential Schools/Colleges more than 1000 inmates
Aqua products processing units
Annexure
(See Under Rule 18)
Categorization of Fire hazardous Buildings/Materials/Trades under the provisions of Telangana Fire Service Act, 1999 and prescribed fee for issuing licences
Theatres and Cinemas Non-AC irrespective of seating capacity including touring talkies.
Other Halls with a closely seated audience (Stage shows and dramas)
Restaurants/Hotels and Dhabas with seating capacity of 30 Nos. to 100 Nos.
Dance Halls
Exhibitions and Assemblies like Industrial, Entertainment, Political, Religious, Cultural, Professional Conferences/Meetings, Major cultural shows and sale exhibitions.
Function Halls, Circuses, Large Tent House.
Non-Residential Schools and Colleges upto 500 inmates but not below 100 inmates.
Non-Residential places for using/storing more than 05 Nos. LPG Cylinders.
Transport Godowns having the floor area upto 2000 Sft.
10.Timber depots, Coal and Oil depots
11.Gas Cylinders (Liquified, dissolved and cryogenic) storage
12.Wholesale shops
13.Commercial showrooms — Temporary and Permanent
14.Automobiles Service Centres
15.Petrol—Diesel outlets having dispensing pumps of 3 Nos. and below
16.Bulk Kerosene storages
17.Software centers having minimum 05 Nos. to 20 Nos. computers
18.Bakeries and Eating houses including Ice cream parlors. Fast food centers etc.
19.Ice Factories
20.Fire crackers sales outlets with temporary licence for two weeks
21.Carpentry and cabinet making
22.Tyre retrading centers
23.Leather processing units/Tanneries
24.Warehouses and Godowns for storage of Jute, Tobacco, Chillies, Cotton, Cashew nuts, Oils, Petrol, Gunny bags, Paper, Celluloid, Timber, Charcoal, Furniture, Food Grains, Cloth, Paints, Varnishes, Spirit, Rubber, Camphor, Artificial Manure and Pesticides, Fiber and Vegetable oils with the floor area of 500 Sft. to 2000 Sft.
25.Timber Mills, Saw Mills, Rice Mills
26.All Small Scale/Cottage Industries
27.Departmental Stores/Super Bazars/Super Markets
28.Fruit Markets
29.Commercial Show Rooms
30.Storages of Electronic and Electrical Goods with floor area below 2000 Sft.
31.All Bars & Restaurants
32.All small scale industries which are covered by Factories Act, 1948
Sodium Peroxide 220. Sodium Sulphide 221. Sodox 222. Solvents (FP below 24.4. deg. cent.) 223. Spirits Industrial 224. Spirits of Wine, Rectified 225. Spirits potable 226. Stains (FP below 24.4 deg. cent.) 227. Strontium 228. Strontium chlorate 229. Strontium Nitrate 230. Strontium Peroxide 231. Sulphuric Acid (Concentrate) 232. Sulphuric Ether 233. Tetralin 234. Tetra Nitro Aniline 235. Tetra Nitro Naphthalene 236. Rhermit 237. Thorium Nitrate 238. Toluene 239. Tri Nitro Aniline 240. Tri Nitro Benzene 241. Tri Nitro Naphthalene 242. Tri Nitro Phenol 243. Tri Nitro Toluene 244. Tri Nitro Apisole 245. Varnishes (FP below 24.4 deg. cent.) 246. Vetriol 247. Waste Celluloid 248. Waste Oily or Greasy 249. Water Proofing Solutions (FP below 24.4 deg. cent.) 250. White Phosphorous 251. Wood Alcohol 252. Wood Spirit 253. Xylene (FP below 24.4 deg. cent.) 254. Xylonite 255. Xylonite Solutions 256. Yellow Phosphorous 257. Zinc Chlorate (Metallic) 258. Zinc Peroxide 259. Zinc Powder 260. Petroleum products storing, packing, Cleansing preparing/ Manufacturing by any process of the following:— i) Non-dangerous Petroleum like Kerosene Oil, Mineral Turpentine, Powerine (Power Kero), Furnace Oil, Vapourising Oil, Aviation Turbine Fuel, Mobile Power Oil etc. ii) Heavy Petroleum like High Speed Diesel (HSD), Light diesel oil (LDO), Tea drier oil etc.
iii) Heavy Oils like Lubricating oils, Vaseline, Petroleum Jellies, White oils, Grease etc. 261. Acid Manufacturers/Dealers 262. Ammonia Manufacturers 263. Asphalt and Bitumen Manufacturers 264. Biscuit Manufacturers 265. Boat Builders 266. Boot and Shoe Factories 267. Brewers 268. Bronze Powder Manufacturers 269. Builders & Applied Traders 270. Butchers & Tripe Boilers 271. Celluloid Goods Manufacturers 272. Chemical Manufacturers 273. Ink (Printing) Manufacturers 274. Jewelers 275. Marine Stores 276. Music Instrument Makers 277. Oil Processing/Recycling/Extraction Units 278. Piano Manufacturers 279. Tarpaulin Makers 280. Turkish Baths
Report on damage caused to premises by members of service during firefighting and rescue operations
Name of the Fire Station:
(1) Date and Time of call received:
(2) Fire Report No. and Date:
(3) Name and Address of the premises where fire occurred:
(4) Description of property involved:
(5) Name and Address of the premises to which damage caused:
(6) Description and details of damage caused to the premises in the course of firefighting and rescue:
(7) Reasons for breaking/pulling down the structures:
(8) Claim of the amount by the party:
(9) Particulars of references to the R&B authorities:
(10) Remarks :
Signature of Officer-in-charge
Form - 3 (See Rule 17) Seizure Memorandum
To
Name:... Date & Time
Address:.. ..Place of Panchanama
..Case No.
..Name & Address of
..Panchas
The following property belonging to you has been seized and detained under Section 14(2) of Telangana Fire Service Act, 1999 for the reasons stated below:
Sl.No
Place from where seized
Particulars of seized property
Quantity
Reasons for seizure and Detension
Signature of the person from whom seized
Signature of the Authority
Signature of the Panchas: 1)
Form -4
(See Rule 17)
Panchanama
Case No .........
Place :
Date :
Time :
Name and Address of the Firm
Name and Address of the person- in-charge present
Name and Address of the Panchas
Sri/Smt .... S/o./D/o./W/o Resident of.. age ....... years Occupation
Sri/Smt : ... S/0./D/0./W/0 Resident of.. age ....... years Occupation
We, the above Panchas are this day.............. Called by Sri … …..designation … Place to
witness the act of seizing certain property from........ ….address of the Firm ........... ............ which were possessed and exposed in the premises of the said Firm. In our presence, the said Fire Officer seized the following mentioned property which we testify to be correct.
Sl.No
Place from where seized
Particulars of seized property
Quantity
Reasons for seizure and Detension
The Panchanama is read over and explained to us and it is correct account of when we saw.
Signature of the Panchas:
Signature of
the Fire Officer
Received the copy of Panchanama
Signature of the person-in-charge of the premises
Form - 5
(See Rule 18)
Application for Grant/Transfer of Fire Service Licence
(1) Name and Address of the premises/Building:
(2) Name of the Firm/Company or Factory/Business :
(3) Name of the Owner/Occupier :
(4) Full postal address for communication:
(5) Description of :
a) Nature of Business, Trade or Process :
b) Commodities and quantities stored/handled
c) Position of storage in relation to No. of rooms/ Floor Area
d) Inflammable liquids and explosive materials
(6) Type of Occupancy:
a) Residential
b) Educational
c) Institutional
d) Assembly
e) Business
f) Mercantile
g) Industrial
h) Storage
i) Hazardous
(7) Building:—
a) General Constructional features:
Low Fire risk - Cement Concrete or brick-walled Or
Medium Fire risk - brick-walled and timber Or
High Fire risk - Mostly timber framed such as timber floors, timber roof, timberstaircase etc.
b) Particulars:—
(i) No. of Storeyes and basement if any
(ii) No. of exits
(iii) Details of ceiling
(iv) No. of staircases and whether enclosed or open
(v) Verandah or balconies
(vi) Attics, Mezzanine floor, lofts, etc.
(c) Details of other structures within 20 metres all around
(i) North
(ii) South
(iii) East
(iv) West
(8) Width of abutting road/street
(9) Maximum amount of Horse Power of Machinery used
(10) Maximum No. of persons present including (occupants, employees, visitors etc.)
(11) Nearest means of communication:
(i) Telephone No.
(ii) Fire Station
(iii) Police Station
(iv) Any other
(12) Details Fire fighting equipment installed
(i) Fire buckets
(ii) Fire Extinguishers (Foam/C02/DCP)
(iii) Hose Reel Hose
(iv) Hydrant systems
(v) Wet-risers
(vi) Sprinklers
(vii) Any other
(13) Details of Fire detection and alarm system
(14) Details of Watch and Ward, if any
(15) Details of water sources
(i) Inside the premises
(ii) Nearest outside the premises
(iii) Overhead and capacity
(16) Details and safety measures for:
(i) Electrical transformer
(ii) Generator
(iii) Control Panel
(iv) Air conditioning and refrigeration system
(v) Heating equipment
(vi) Storage of cylinders
(vii) Any other
(17) Particulars of fee remitted Challan No. and Date
Certified that the above particulars furnished are true to the best of my knowledge.
Date: Place:
Signature ofthe applicant
Form - 6 [See Rule 19(1)] Fire Service Licence
Licence …………
Date: ....... …………
Name and Address of the premises/Building:
Name of the Firm/Company or Factory/Business:
Name of the Owner/Occupier:
Full postal address for communication:
Description of:—
a) Nature of Business, Trade or Process:
b) Commodities and quantities stored/handled
c) Position of storage in relation to No. of rooms/Floor Area
d) Inflammable liquids and explosive materials
e) Maximum Horse Power installed
Type of Occupancy:
Licence is hereby granted under Section 17 of the Telangana Fire Service Act, 1999 to the above premises, within the jurisdiction of ................... Fire Station, subject to the conditions prescribed under the Telangana Fire Service Rules.
This Licence is valid up to--- or till it has been duly cancelled.
Office Seal with date.
Signature of Issuing Authority
Form - 7
[See Rule 19(5) and 21(4)]
Form of Appeal
Before the Director General of Fire Services (Appellate Authority)
Appeal No .............. dated ........... of Sri .............. S/o./D/o./
W/o ................ resident of..............
Appellant
Authorized Officer (Designation… …..) Respondent
Appeal under Rule .......... framedunder Section 17(2) of Telangana Fire Service Act against the notice/order of ................ (Respondent)
Sir,
The Appellant respectfully submit as under:—
Statement of Facts
Ground of Appeal
Appeal is within time i.e. within 30 days from the date of receipt of order/notice 4) No other appeal or any matter relating to the subject matter to this appeal is pending in any Court of Law.
Signature of Authorized
Representative if any
Signature of Appellant
Verification
........... the appellant do hereby declare that what is stated above is true to the best of my personal knowledge and belief and that I have not suppressed any material facts.
Verified today, the ................ day of ......................year...............
Place:
Signature of Appellant
Signature of Authorized
Representative if any
Form - 8
[See Rule 21(2)]
Application for renewal of Fire Service Licence
Name and Address of the premises/Building
Name of the Firm/Company or Factory/Business
Name of the Owner/Occupier
Full postal address for communication
Description of:—
a) Nature of Business, Trade or Process
b) Commodities and quantities stored/handled
c) Position of storage in relation to No. of rooms/ Floor Area
d) Inflammable liquids and explosive materials
Type of Occupancy:—
a) Residential
b) Educational
c) Institutional
d) Assembly
e) Business
f) Mercantile
g) Industrial
h) Storage
i) Hazardous
Existing Licence No. and Date and Designation of Issuing Authority
Particulars of fee remitted Challan No. & Date
Details of modification/additions done if any
a) Structural
b) Storage
c) Quantity of Commodities/inflammable liquids/ Explosive materials
d) Business
e) Electrical appliances
f) Means of Escape
g) Any other, furnish details
Certified that the above particulars furnished are true to the best of my knowledge.
Place:
Signature of the Applicant
Date:
Form - 9
[See Rule 25(1)] Form of Notice to inspect the premises
empoweredby Section 20 of the Telangana Fire Service Act, 1999 and Rule 25( 1) of Telangana Fire and Emergency Operations and Levy of Fee Rules, 2006 do hereby give you notice that on expiry of not less than three hours from the time of service of this notice upon you i.e. date......... and time........., I shall enter and inspect your building/premises bearing No.............. ..............located at............................... for the purpose of ascertaining the adequacy or contravention of fire prevention and fire safety measures as required to be provided under Rules framed under the Telangana Fire Service Act, 1999.
Signature of the Inspecting Officer
To
.Owner/Occupier
Form - 10 [See Rule 26(1)] Inspection Report
Name and Designation of the Inspecting Officer
Date of Inspection:
Time of Inspection:
Name and Address of the premises/Building :
Name of the Firm/Company or Factory/Business :
Name of the Owner/Occupier
Name of the person-in-charge present during : the Inspection
Full postal address for communication
Description of:—
a) Nature of Business, Trade or Process
b) Commodities and quantities stored/handled
c) Position of storage in relation to No. of rooms/ Floor Area and adequacy of Fire precautions adopted for storage of hazardous goods
d) Inflammable liquids and explosive materials
e) Raw materials
f) Machinery
g) Electric motors
h) Heating equipment like boilers, etc.
i) Commodities and quantity applied for in case of storage of chemicals with reference to Explosive and Petroleum Rules
j) Type of occupancy
Building:—
a) Constructional features:
i) General
Low Fire risk - Cement Concrete or brick-walled Or
Medium Fire risk - brick-walled and timber Or
High Fire risk - Mostly timber framed such as timber-floors, timber roof, timber-staircase etc.
c) Particulars:—
i) No. of Storeyes and basement if any;
ii) No. of exits
iii) Details of ceiling
iv) No. of staircases and whether enclosed or open
v) Verandah or balconies
vi) Attics, Mezzanine floor, lofts, etc.
vii) Whether prescribed distance in respect of means of escape is maintained or not.
d) Details of other structures within 20 metres all around the building and open spaces/approach for fire vehicle
Structures
i) North
ii) South
iv) West
Width of abutting road/street
Maximum amount of Horse Power of Machinery used
Maximum No. of persons present including (occupants, employees, visitors etc.)
Nearest means of communication:
i) Telephone No.
Form - 11 [See Rule 26(1)] Periodical Inspection Report
Licence No ..........
Date of Inspection ........
Time of Inspection ........
Name & Designation of Inspecting Officer
Name and Address of the premises/building
Name of the Firm/Company/business/factory etc.
Type of Occupancy
Name of the Occupier/Owner
Name of the person-in-charge present during the inspection
Date of previous inspection if any
Details of notice served if any
Breach of conditions/recommendations of Fire Safety measures
Compliance details of the Owner/Occupier
Details of the accidents occurred from the last inspection
i) Property involved
ii) Property damaged
iii) Cause of Fire
iv) Particulars of insurance claimed
Observations made by the Inspecting Officer
Recommendations:
Date:
Place
Signature of the Inspecting Officer.
Candles
Cane Fiber
Cape Palma Fiber
Caraway Chaff
Carbolic Oils
Carbon
Carbon Black
Carbon Di-sulphide
Carbonyl Chloride
Caraube
Cassia Leaves
Castor Oil
Cattle Food Cake
Caustic Potash
Caustic Soda
Cello-solve Butyl
Cello-solve Acetate
Cerasine
Charcoal
Charcoal Black
Chickle
China Grass (Vegetable Fibre)
Chlorobenzene
Chlorine
Chloromates of all kinds
Cloth Asthalted
Cloth Tarred
Cloth Oiled
Coal Gas
Coal Pitch
Coal Tar
Coal Tar Dyes
Coca Butter
Coca Nut Fiber
Coconut Oil
Cod Oil
Coir Dust
Coir Fiber
Coir Matting
Coir Rope
Coir Yarn
Cole Nuts
Collophony
Common Resine
Confetti
Confetti Bombs
Congo Fiber
Copal
Copal Varnish
Copper Sulphide
Copra
Copra Cake
Copra Meal
Cordage sisel
Cork Dust
Cotton in fully pressed bales or otherwise
Cotton Flock
Cotton Grass
Cotton Linter
Cotton seed Cake
Cotton seed Oil
Cotton seed Screenings
Cotton Straw
Cotton Waste
Cowrie
Creosote
Creosote Oil
Cresols
Cresilic Acid
Crin (Vegetable fiber)
Crotonaldehyde
Cubra Bast
Cumene
Cumol
Culed Vegetable Hair (Vegetable Fiber)
Cus Fiber (Cus Cus Root)
Cyanogen
Cymene P
Cymol
Dammer
Damp Course
Date Palm Fiber
DLT Liquid
Dead Oil
Dackance
Palm Nuts 399. Palmerah Fiber 400. Pampas Plumes 401. Paper 402. Paper Shavings 403. Papyrous (Vegetable Fiber) 404. Paraffin Vax 405. Para Matta Grass (Vegetable Fiber) 406. Para Nitro Acetanylide 407. Para Nitro Phenol 408. Para Nitro Sodimethyl Aniline 409. Peat Dust 410. Peat Mould 411. Permanganates of all kinds 412. Peroxide of all kinds 413. Persulphates of all kinds 414. Petroleum Ether 415. Petroleum Jelly 416. Petroleum Oils 417. Pharmaceutical Chemicals and Drugs 418. Phenol 419. Phosphorous Red 420. Phosphorous Penta Chloride 421. Phosphorous Sulphides 422. Phosphorous Trichloride 423. Photographic Powders 424. Pissava of all kinds (Vegetable Fiber) 425. Pine apple Grass 426. Pine Bark 427. Pita Fiber 428. Pitch 429. Plantaine Fiber 430. Poisons and Polishing Liquids 431. Pontionac 432. Potassium Bichromate 433. Potassium Hydroxide 434. Potassium Permanganate 435. Potassium Persulphate 436. Potassium Sulphinde 437. Pyrene 438. Raffia (Vegetable Fiber) 439. Rags (Clean)
Stearlime
Straw (Vegetable Fiber)
Straw developers
Straw Plants
String Tarred
Suint
Sulphide, Waste Liquor
Sulphur Chlorides
Sulphur Dyes
Sulphur Praecip-1 LB Packets
Sulphuric Acid Dilute
Sunn Hemp (Vegetable Fiber)
Tallow
Tampico Hemp (Vegetable Fiber)
Tar of all kinds
Tar Oils and their liquid products
Tarpaulins
Tarpaulin Papers
Teasles
Terebene
Tetra Nitro Methyl Aniline
Textile Materials Oiled
Thistle down (Vegetable Fiber)
Thus
Thyme
Tow of all kinds
Tree Cotton (Vegetable Fiber)
Tri Cnesyl Phosphate
Tri Sodium Phosphate
Tula Fiber
Turkey Red Oil
Turpentine
Twine Tarred
Varnishes (FP above 24.4 deg. cent.)
Vaseline
Vegetable Black
Vegetable Down
Vegetable Fibers of all kinds
Vegetable Horse Hair
Vegetable Silk
Vegetable Wool
Wagner Lockheed
Waste of all kinds
Water proofed cloth using an oil based solution
Water proofing solutions (FP above 24.4 deg. cent.)
Wax of all kinds
White Spirit
Wood Fiber
Wood flour
Wood Meal
Wood Wool
Wool Grease
Xylene (FP above 24.4 deg. cent.)
Yucca Fiber
Zacaton (Vegetable Fiber)
Zinc Bi-chromate
Zinc Dust
Acetylene Engineers
Agricultural implement manufacturers
Artificial flower Manufacturers
Auctioneers
Bag Manufacturers
Bedding and Mattresses Manufacturers
Bill Posters
Biscuit Manufacturers (Small Scale)
Blacksmiths and Farriers
Bottle Merchants
Brush Makers
Builders and Applied Trades
Cap and Hat Makers
Carbide of Calcium Makers
Carmen
Carriers
Case Makers
Chemists
Clothiers and Out fitters
Colour Manufacturers
Comb Manufacturers
Coopers
Cork Merchants
Curriers and Tanners
Decorators
Drapers
Druggists
Dyers and Cleaners
Electrical Suppliers
Enamellers
Muslin Clippers
Envelope Makers
Export Pakers
Fancy Box Makers and Goods Traders
Fish Curers and Fried Fish shops
Floor Cloth Manufacturers
Forage Merchants
Founders
French Polishers
Furriers
Galvanizers
Gas Singers and Cloth Pressers
Glass Works
Glovers
Glue Merchants
Gramaphone and Record Traders
Grossers and Coffee Roasters
Gun smiths
Garment and Textile Manufacturers
Hatters
Hops
Hossiers
Hot Pressers
Incandescent Mantle Makers
India Rubber and Guttapercha Manufacturers
Iron Founders
Job Masters
Joiners
Lace Manufacturers
Lacquer Manufacturers
Launderies
Litho Graphic Printers
Munition Makers
Milleners
Mill Wrights
Packing Case Makers
Paper Bag and Box Makers
Rag and Waste Dealers
Sack and Bag Manufacturers
Skin Dressers
Soap Boilers
ii) Fire Station
iii) Police Station
iv) Any other
Details of Fire fighting equipment installed:
i) Fire Buckets
ii) Fire Extinguishers (Foam/C02/DCP)
iii) Hose Reel Hose
iv) Hydrant systems
v) Wet-risers
vi) Sprinklers
vii) Any other
Details of Fire detection and alarm system
Details of Watch and Ward, if any
Details of water sources
i) Inside the premises
ii) Nearest outside the premises
iii) Overhead and capacity
Details of safety measures for:
i) Electrical transformer
ii) Generator
iii) Control Panel
iv) Air-conditioning and refrigeration system
v) Heating equipment
vi) Storage of cylinders
vii) Any other
Particulars of fee remitted Challan No. and Date
Recommendations:
Commodities and quantity
Location
Storage arrangements
Fire precautionary measures suggested
Structural recommendations
Protective measures against exposure hazard
General
Whether issue of licence is recommended, if not, specify the reasons thereof.
Signature of Inspecting Officer
Date: Place:
Buildings
Instructions for filling the Check List
(1) Read explanatory notes carefully, before filling the form.
(2) The requirements listed need to be fulfilled to comply with rules and Regulations. If an item is complied with mark 'Yes' and if an item is not complied with, Mark 'No'. If an item is not applicable to the particular building, mark 'Not Applicable' (NA).
(3) In the pre-construction stage, the marking may be Yes/No/NA. In the post-construction stage full details in all columns should be filled in and relevant Vendor literature should be provided for fire safety systems/ items.
(4) Portable fire extinguishers and miscellaneous fire safety measures will be checked, before issuing of final NOC for enabling the Municipal Authority issue occupancy certificate and hence the same should be envisaged in the planning stage.
(5) The Checklist is not all-inclusive. The architect should make sure that all Applicable rules and regulations are fully complied with (Telangana Fire Service Act 1999/NBC, All applicable Building Laws.)
(6) The items with '*' mark are mandatory.
(7) The design and plan of the building shall be made and countersigned by a qualified civil or structural Engineer, an Architect (NBC-Part 2) and the Owner/Builder.
(8) If more than one block is proposed, you should attach separate checklist for each block.
(9) Submit proposed construction plan -5 sets (site plan, Basement Floor Plans, Stilt Floor Plans, floor wise plan, terrace plan, Section and Elevation duly marking fire safety systems along with General information proforma and 5 sets of checklist dully filled in, Estimates towards the provision of fire safety systems, 15% of the estimates of Fire Safety system as Bank Guarantee, Undertaking on Rs 100/- Stamp-paper and copy of the Challan towards the payment of Fire precaution Fee @ Rs 10/- per Sq mtr of total built-up area including basements and stilts areas).
(10) Checklist should be neatly typed without any corrections. Checklists with overwriting, corrections and interpolations shall be summarily rejected.
1
*1.1
Name and Address of the Applicant
*1.2
Address of the Premises:
*1.3
Address for Correspondence (provide phone number, Fax and email id if any)
*1.4
Designation and Address of Licensing Authority issuing building permit to whom NOC has to be sent (Tick the appropriate authority)
GHMC/HUDA/TSIIC/VUDA/VGTUDA/KUDA/TUDA/Others
*1.5
Name of the Block
1.6
Height of the Block
Enter the Height of the Building __mtrs(Note for the building above 30 m. height, the builder shall submit Additional emergency plan of action, including provision and maintenance of hydraulic platform with capacity to have an access upto the terrace of the building, round the clock with officer and crew.
*1.7
Type of building occupancy (refer NBC-4, 3.1; 3.4.7, Table 23):
____
*1.8
Sub Occupancy Type
____
*1.9
Area of the site in Sq. Mtrs (minimum 1000 Sq. Mtrs)
*1.10
(i)Total Built-up area of all floors including basements & stilts(in sqm)
____ Sq. Mtrs.
(ii) Fire precaution fee remittance particulars
Fire Precaution Fee Payment should be made in the form of Challan Only @ Rs 10/- per Sq. mtr. for the total built-up area including basement and stilt areas.E-Seva User charges should be paid in the form of cash.Challan No., Amount and Date_Name of the Bank_Name of the Branch_Treasury challan under the following head of account SM: 0070 - Other Administrative Services.MH:109 - Fire Protection and ControlSH: (02) Fees on FireDH: 001- Other ReceiptsDDO Code - 25001005001
*1.11
Surrounding of the Premises
North ____South ____East ____West ____
*1.12
Open space front & other 3 sides of the Block
Open space front & other 3 sides (NBC-Part 3-4.6; 8.2.3.1, 9.4.1(a); Part 4-3.4.6)Note:- Access space vide a) NBC-Part 3-4.6, "additional" to open spaces reqd. vide Part 3-8.2/3, as per NBC-Part 4-3.4.6.1.,) additional to parking space per Part 4-7.4.1.c. If ht. exceeds 15 mtrs. refer NBC- Part 3-8.2.3.1 for minimum open space, around the building and 9.4.1(a) for front open space.
*1.12.1
Open space on North side ____ Metres.
*1.12.2
Open space on South side ____ Metres.
*1.12.3
Open space on East side ____ Metres.
*1.12.4
Open space on West side ____ Metres.
*1.12.5
Front side ____ Direction(East/West/North/South)
1.13
Projections into open spaces:
1.13.1
Front _ Metres _ direction
Front _ Metres _ direction
Front _ Metres _ direction
Front _ Metres _ direction
Front _ Metres _ direction
Front _ Metres _ direction
1.13.2
Side1 _ Metres _ direction
Side1 _ Metres _ direction
Side1 _ Metres _ direction
Side1 _ Metres _ direction
Side1 _ Metres _ direction
Side1 _ Metres _ direction
1.13.3
Side2 _ Metres _ direction
Side2 _ Metres _ direction
Side2 _ Metres _ direction
Side2 _ Metres _ direction
Side2 _ Metres _ direction
Side2 _ Metres _ direction
1.13.4
Rear _ Metres _ direction
Rear _ Metres _ direction
Rear _ Metres _ direction
Rear _ Metres _ direction
Rear _ Metres _ direction
Rear _ Metres _ direction
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
Note:- Projected Balcony at higher floors should not exceed 1.20 mtrs. as per clause 8.4 of Part 3, NBC and sunshades over windows/ventilators or other openings not to exceed 0.75 mtrs.
*1.14
Block Details
*1.14.1
Number of floors _Number of Basements _Number of Stilts /Ground floor _
Number of floors _Number of Basements _Number of Stilts /Ground floor _
Number of floors _Number of Basements _Number of Stilts /Ground floor _
Number of floors _Number of Basements _Number of Stilts /Ground floor _
Basement ____Stilt ____Ground ____
1.19
Ramps
Proposed to provide __ramps (If no basement is there for the building, please enter 'NA'.)Specify Ramp DetailsWidth of Ramp in mtrs. SideRamp 1Ramp 2Note:- As per cl 12.9.3 of open ramps shall be permitted if they are constructed within the building line.
*1.20
Staircases
*1.20.1
No. of Internal staircase ____(Minimum 1)No. of External staircase ____(Minimum 1)All the staircases shall be designed to abut one of its sides to the external wall.
Internal Stair Case Details:
Internal Stair Case Details:
Internal Stair Case Details:
Internal Stair Case Details:
*1.20.2.1
Internal Staircases (Minimum width 1.50 meters) for other than Assembly and Institutional Occupancy, for Assembly and Institutional Occupancy Minimum internal staircase width should be minimum 2.0 metersNo Location From To Width of staircases....... ...... ...... ...... metersFloor Floor ......metersStaircase 1Staircase 2Staircase 3Staircase 4Staircase 5
*1.20.2.2
Travel distance __mtr. distance from the farthest point and __mtr. distance from the dead-end of the corridor to the staircases (11⁄2 times permitted travel distance is acceptable if entire building is proposed with sprinkler system) (Number of staircases to comply with travel distance NBC-4 - 4.5 .If there are more than 1 internal staircase, one of the staircases may be extended to the basement and it should terminate at ground floor level and separate staircases shall be provided to reach the basement parking areas from ground floor and the same should be separated at ground level by ventilated lobby with discharge points to 2 different ends through enclosure.)
*1.20.2.3
Width of the Threads ____ cm
*1.20.2.4
Height of the riser ____ cm
*1.20.2.5
Number of riser ____ per flight
*1.20.2.6
Height of the hand rails ____ mtr (should be/ mtrs)
*1.20.2.7
The gap between two vertices ____cm (should not exceed 15 cm)
*1.20.2.8
Head room clearance __mtr.
External Staircase details:
External Staircase details:
External Staircase details:
External Staircase details:
*1.20.3.1
External Staircases:No Location From To Width of staircase ...... ...... ...... ......mtrs.Floor Floor
Booster Pump 1 Booster Pump 2
*1.23.11
_______ Number of Fire lifts Fire Lift Details: Capacity Fire Lift 1 Fire Lift 2 (Note minimum one Fire Lift with capacity Not less than 545 kgs / 8 persons lift for every 1200 sq. mtrs. area as per NBC part 4 - Annexure C 1.5)
*1.24 Bank Guarantee:
15% of the estimates of Fire Safety Systems Rs____________ as Bank Guarantee.
*1.25
Nearest Fire Station:
Nearest Fire Station__________________ and Telephone Number_________
1.26
Public Address System
_____________ (Provided/Not Provided)
II
S.No
Description
Description
*2.1
Whether Building Owner/Occupier Name and his address is filled in and signed
Whether Building Owner/Occupier Name and his address is filled in and signed
YES
NO
*2.2
Whether Location and Address of the Building/Site is filled in
Whether Location and Address of the Building/Site is filled in
YES
NO
*2.3
Whether Buildings plans include the following (for filling 2.3.1 to 2.3.34, please refer NBC-Part 2-12.2.5.1)Note: The plans should be to scale. All plans shall be not less than 1:100 scale
Whether Buildings plans include the following (for filling 2.3.1 to 2.3.34, please refer NBC-Part 2-12.2.5.1)Note: The plans should be to scale. All plans shall be not less than 1:100 scale
*2.3.1.1
Whether 5 sets of Checklist duly filled in all columns and signed are submitted?
YES
NO
*2.3.1.2
Whether 5 sets of site plan duly marking open places on all sides is submitted.
YES
NO
*2.3.1.3
Whether 5 sets of Floor wise plans including Basements/Stilts duly marking fire safety systems are submitted.
YES
NO
*2.3.1.4
Whether 5 sets of Terrace plans are submitted.
YES
NO
*2.3.1.5
Whether 5 sets of Section plans are submitted.
YES
NO
*2.3.1.6
Whether 5 sets of Elevation plans are submitted.
YES
NO
*2.3.2.1
Width of the abutting street (to be not less than 12 mtrs.) (NBC Part 3-4.6)
YES
NO
2.3.2.2
Show if it is terminating in dead end (NBC- Part 3-4.7; Part4-3.4.6)
*2.3.3
Area of the plot
YES
NO
*2.3.4
Plan of all floors with staircases, corridors
YES
NO
*2.3.5
Lift well, ramps,(if provided)
YES
NO
*2.3.6
Two section dwgs, through stairs(NBC- Part 2-12.2.5.1.b/c)
YES
1642)
2.5
Access/Open space
2.5.1
Dead end in abutting street allowed only in residential bldg. below 30 mtrs. ht, in which case,81 sq. mtrs. turning space reqd. (NBC- Part 3-4.7;)
Approach to bldg. and access space on all sides up to 6 mtrs. width shall (refer to NBC- Part 3-4.4.2, / 4.6,/8.4, 1.d, /Part 4-3.4.6, 3.4.6.1.c/d, 5.1.6)
*2.5.3.1
be hard surfaced for 45 ton fire vehicles and be motorable
YES
NO
2.5.3.2
if have roof on water tank or bridge, if any in access route, should withstand a load of 45 ton fire vehicle. (NBC-Part4-5.1.6)
YES
NO
NA
*2.5.3.3
This space of 6 mtrs., for access, shall be maintained free of parking, and kept free of any obstructions, structures or fixtures up to ht. of 4.5 mtrs., above which 1.25 mtrs. unenclosed balconies are allowed
YES
NO
2.6
Exit Requirements
2.6.1
General Exit Requirements (B-20/21; NBC-Part 4-4, appdx C) (Note-Lift and escalators shall not be considered as exits.(NBC-Part 4-4.2.2))
*2.6.1.1
Every public place to have sufficient safe exits-without passing through another occupied unit.( NBC-Part 4-4.2.4/4.2.11)
YES
NO
*2.6.1.2
All escape Exit routes to have clearly visible & illuminated signs with battery backup emergency alternate power supply, (NBC-Part 4-4.2.7; 4.16.3/4/10, C1.14b)
YES
NO
*2.6.1.3
Fire-check doors for fire resistance of two hour to prevent spread of fire/ smoke, in escape routes, particularly at entrance to lifts and stairs which are prone to funnel/ flue effect ( NBC-Part 4-4.2.9)
YES
NO
2.6.1.4
Exits to suffice simultaneously for assembly and other occupancy, if any, unless Fire department determines that, condition are such that simultaneous occupancy will not occur -(NBC-Part 4- 6.4.4.8/9)
YES
NO
NA
*2.6.2.1
Number of persons within any floor area or occupant load shall be based on actuals, but not less than that given in (NBC- Part 4- 4.3; Table 21)
YES
NO
*2.6.2.2
Locate exit stairs, so that travel distance does not exceed 22.5 mtrs. for residential, educational, institutional and hazardous occupancies and 30 mtrs. for assembly, business and storage and 45m for industrial buildings. These should be remote to one another and should provide exit in different directions. For basements travel distance should not exceed 15 meters (NBC- Part 4- 4.5)
YES
NO
*2.6.2.3
Doorways to be min. 100 cms (200 cm. for assembly areas)
YES
NO
*2.6.2.4
Open into corridors or through landings into enclosed staircases for continuous protected egress (NBC-Part 4- 4.7)
YES
NO
*2.6.2.5
Staircases shall be of enclosed type (NBC-Part 4-4.6)
YES
NO
*2.6.2.6
No. and sizes of exit staircases to depend on 6b(1 to 3) above and 7A5 (NBC-Part 4-4.3/4/5&6)
YES
NO
*2.6.2.7
Exit doors to be open able from served side, without keys.(NBC-Part 4-4.7.5)
YES
NO
2.6.3
Corridors and Passageways
*2.6.3.1
The width of the above shall not be less than the aggregate required width of exit doors leading in direction of egress.(NBC- Part 4-4.8.1)
YES
NO
*2.6.3.2
The above (& stairs/lifts) shall have fire/smoke resistant doors
YES
NO
*2.6.3.3
Have adequate ventilation(NBC-Part 4-4.8.3)
YES
NO
*2.6.3.4
*2.7b.4
To have no wall/window opening, close to it (NBC-Part 4-4.11.4)
YES
NO
*2.7b.5
Open able vents/ducts to outer air be provided at landings to facilitate venting of smoke, if any, and for rescue/fire fighting (NBC-Part 4 C.1.4)
YES
NO
*2.7b.6
Route to be Always free of any obstructions /doors shall be open able from the served side without use of a key (NBC-Part 4-4.11.6)
YES
NO
*2.7b.7
Shall be of non-combustible materials and doors leading to it shall have the reqd. fire resistance. (NBC- Part 4-4.11.6)
YES
NO
*2.7b.8
Fire escapes not to be taken into account in calculating evacuation time.(NBC-Part 4-4.11.10)
YES
NO
*2.7b.9
Width/tread, to be not less than 1.25 meters/.25 metres resp.; riser not more than 19 cm. and flights/angle not more 15/45 degrees, resp. (NBC-Part 4, 4.11.7/8). However, the corresponding dimensions for internal stairs ie: width/tread/riser at 150/25/15 cm. resp. are much preferred to ensure safer evacuation.)
YES
NO
2.8
Miscellaneous Exit Items
2.8.1
Fire Tower
2.8.1.1
Fire Tower is the preferred escape route, being an enclosed staircase, approached from floors, thru. landings separated from floors and stairs by fire-resistant doors and open to outer air (NBC-Part 4-3 & 4.13)
YES
NO
NA
2.8.1.2
For business, mercantile, institutional, theaters, if >8 stories or >24 mtr., in height, at least one fire tower is reqd.
YES
NO
NA
2.8.2
Horizontal Exits
2.8.2.1
To have with the same width at least one fire door of self-closing type (NBC-Part 4-4.12.1/2)
YES
NO
NA
2.8.2.2
Doors to be openable at all times from served side(s) (NBC- Part 4 4.12.5)
YES
NO
NA
2.8.2.3
Refuge area of 15 m2 or an area equivalent to 0.3 m2 per person to accommodate the occupants of two consecutive floors, whichever is higher, shall be provided as under.(a) For Floors above 24 m and upto 39 m – one refuge area immediately above 24 m(b) For Floors above 39 m – one refuge area on the floor immediately above 39 m and soon after every 15 m
YES
NO
NA
2.8.3
Ramps
2.8.3.1
To be not steeper than 1 in 10 and Never steeper than 1 in 8. Surface to be skid proof NBC-Part 4-4.14)
YES
NO
NA
*2.8.3.2
To never abut the street without level space, so as to provide safe sighting, before driving into the street. (NBC-Part 3-10).
YES
NO
2.8.3.3
In plots over 2000 sq. mtrs. Ramps shall be within bldg, line, for safety reasons
YES
NO
2.9.
Electrical Safety
*2.9.1
To comply with Indian Electrical Rules, including related Indian standards/Codes stipulated therein ; NBC Part 8-2 ; N.E.C.- Part 3-3; and IS-4878-14 ; IS- 1646 & 732.
YES
NO
*2.9.2
Elec. Installations shall be by licensed electrical contractor & supervised by holder of competency-certificate/permit issued by government. Appropriate certificates reqd.(IS-732-3.5)
YES
NO
*2.9.3
Completion drawings showing all circuits to enable functional checks to verify compliance with applicable rules(NBC- Part 8-3-9.1.5/9.2; IS 732.-3.1/.4.1/.5/.9)
YES
NO
*2.9.4
Specific Requirements
*2.9.4a.1
Emergency and escape lighting powered by source independent of normal power, for stairs/ exit routes & fire alarm
YES
NO
*2.9.4a.2
With One and half hrs. battery backup (NBC-Part 4-4.16 ; appendix-D1.14)
YES
NO
NA
*2.9.4b
Alternate/Emergency generator fed, separate, direct power circuits for item 2 (refer NBC-Part 4-C.1.5.p ;1.6.4.3 ; 1.12,14,15)
NA
*2.9.4b.1
Fire pumps, lifts YES NO
*2.9.4b.2
Smoke Exhausters YES NO
*2.9.4b.3
Emergency Lighting YES NO
*2.9.4b.4
Fire Alarm /P.A. Systems YES NO (Note: Auto start and auto switch over from normal to emergency source should be ensured)
2.9.4c
Transformers, if in basement to have enclosure of 4hr. ratingYES NO (NBC-Part 4-C.1.16.c)
NA
2.9.4d
Transformers room/enclosure, location and ventilation /YES NO exhaust to be such that no smoke or fumes there from can ingress into exit/escape routes or parking or other parts of the bldg(NBC-Part 4-6.4.6.5)
NA
*2.9.4e
Transformer plinth should be at least 15 cm. above gradeYES NO and if oil filled should have curbs to prevent egress of leaking oil into any parking area.(NBC- Part 8-2-4.2.2.c/g.)
2.9.4f
Periodical verification of efficacy of emergency/alternateYES NO power supplies and related escape and fire safety equipment.(IS-1646-3.6&11.6)
NA
*2.9.4g
Compliance with I.S.1646;732; 10028, regarding fire safety of bldg., electrical wiring & transformers resp.
2.9.4h
Indoor transformers to have auto High velocity water spray orYES NO Emulsifying system (IS-15.10.3)
NA
2.9.4i
Transformer shall have soak pit, fencing and provided withYES NO 45 ltr foam trolley.
NA
2.9.5
Power circuits YES NO
NA
*2.9.5.1
The lighting in, passageways, stairways, exits, and parts ofYES NO bldg. open to public, should be divided into two halves, each half being fed by separate circuit, controlled by switches, located remote from each other.(IS-1646)
*2.9.5.2
Electrical fires being common cause of fires, strict compliance I.E.R 30 (ISI, compliant electrical material) and IS-732 & NBC- Part 8-2,(for electrical wiring), is essential
YES
NO
*2.9.6
Lightning protection per IS- 2309. (NBC- Part 3-19)
YES
NO
2.10
Fire Protection (The following aspects should be taken care of.)
Fire Protection (The following aspects should be taken care of.)
2.10a
Building Design
*2.10a.1
Type of construction to comply with item 4, above, to prevent rapid spread of fire, smoke or fumes which may otherwise contribute to loss of lives and property. Fire resistance ratings to comply with NBC-Part 4 cl-3.3 Table 1. (Any deviations to be specifically, noted)
YES
NO
2.10a.2
If a bldg. has more than one occupancy it shall comply with requirements of the most hazardous one, unless 4 hr. rated separating wall is provided (NBC- Part 4-3.4.7)
YES
NO
NA
*2.10a.3
Fire resistant doors, 1 hr. rated, in escape routes, particularly at entrance to lifts, staircases , per 7.a-7, above (NBC-Part 4-4.2.4& IS-361)
YES
NO
*2.10a.4
Doorway or opening in separating walls/floors to limit spread of fire, smoke by use of 2 hr. rated fire resistance doors/steel rolling shutters (NBC- Part 4-3.4.8 & 3.4.8.1; IS-12458)
YES
NO
*2.10a.5
Openings in walls/ floors for cables, plumbing etc. to be in ducts/shafts enclosure of 2hr.fire-resistance, with 1 hr. rated inspection doors.(NBC-Part 4-3.4.8.2/3 & C.1.9)
YES
NO
*2.10a.6
Seal space between cables etc. and shaft ,with fillers, to stop fire at every floor level.(NBC-Part 4-3.4.8.3)
YES
NO
*2.10a.7
Surface finishes on walls/ ceilings/façade shall minimize the spread of fire or toxic fumes (NBC- Part 4-3.4.15.1;C.11 )
YES
NO
*2.10a.8
Use "Class 1 flame-spread", surfacing material, and fabric materials used for decor, carpets, curtains etc. per IS 2777.(NBC-Part 4-3.4.15.2,6.4.6.1,C1.2 & 11.1)
YES
NO
*2.10a.9
Walls, partitions or floors lined with combustible material, to have surfaces conforming to IS 1642, to prevent rapid fire spread, hampering escape of occupants. (NBC-Part 4-3.4.15.5)
the provisions of Part 4 Fire and Life Safety.
2.10.d.11
Each Basement shall be separately ventilated. Vents withYES NO cross sectional area (Aggregate) not less than 2.5% of the floor area spread evenly round the perimeter of the basement shall be provided in the form of grills, or breakable stall board lights or pavement lights or by way of shafts. Alternatively, a system of air inlets shall be provided at basement floor level and smoke outlets at basement ceiling level. Inlets and extracts may be terminated at ground level with stall board or pavement lights as before, but ducts to convey fresh air to the basement floor level have to be laid. Stall board and pavement lights should be in positions easily accessible to the fire brigade and clearly marked' Smoke outlet' or air inlet with an indication of area served at or near the opening.
NA
2.10.d.12
The staircase of basements, shall be of enclosed type havingYES NO fire resistance of not less than 2h and shall be situated at the periphery of the basement to be entered at ground level only from the open air and in such positions that smoke from any fire in the basement shall not obstruct any exit serving the ground and upper stores of the building and shall communicate with basement through a lobby provided with fire resisting self closing doors of 1h resistance. For travel distance see 4.5 part 4 NBC. If the travel distance exceeds as given in table 21, Part 4, Additional staircases shall be provided at proper places.
NA
2.10.d.13
In Multi-storey basements, intake ducts may serve all YES NO basement levels, but each basement level and basement compartment shall have separate smoke outlet duct or ducts. Ducts so provided shall have the same fire resistance rating as the compartment itself. Fire rating may be taken as the required smoke extraction time from smoke extraction ducts.
NA
2.10.d.14
Mechanical extractors for smoke venting system from lowerYES NO basement levels shall also be provided. The System shall be of such design as to operate on actuation of heat/smoke sensitive detectors or sprinklers, if installed, and shall have a considerably superior performance compared to the standard units. It shall also have an arrangement to start it manually.
NA
2.10.d.15
Mechanical extractors shall have an internal lockingYES NO arrangement, so that extractors shall continue to operate and supply fans shall stop automatically with the actuation of fire detectors.
NA
2.10.d.16
Mechanical extractors shall have an alternative source of supply
YES
NO
NA
2.10.d.17
Ventilating ducts shall be integrated with the structure and made out of brick masonry or reinforced cement concrete as far as possible and when this duct crosses the transformer area or electrical switch board, fire dampers shall be provided.
YES
NO
NA
2.10.d.18
If cutouts are provided from basements to the upper floors or to the atmosphere, all sides cutout openings in the basements shall be protected by sprinkler head at close spacing so as to form a water curtain in the event of fire.
YES
NO
NA
*2.10e
First aid fire extinguishers should be provided as per IS-2190:1992 & NBC-Part 4-5.1Note:- The following minimum number of fire extinguishers should be provided.
*2.10e
i) One ABC powder extinguishers of 5 kgs. capacity and 2 number of fire buckets filled with clean, dry, fine sand should be provided for every 8 cars.
YES
NO
*2.10e
ii)One extinguishers of 2 kgs. capacity should be provided near the entrance to each main switch board room.
YES
NO
*2.10e
iii) 2 ABC powder extinguishers of 5 kgs. capacity should be provided near transformer, if installed.
YES
NO
*2.10e
iv) 2 ABC powder extinguishers of 5 kgs. capacity should be provided inside each lift room.
YES
NO
*2.10e
v) 1 water pipe gas cartridge extinguisher of 9 ltrs capacity should be kept near each staircase landing on every floor.
YES
NO
*2.10e
vi) Scale of suitable extinguishers for other areas shall be collected before approaching the department for final clearance, after finalizing utility of each area.
YES
NO
vii) All the extinguishers suggested above should be with BIS Mark and should be located at an easily accessible position without obstructing the normal passage.
YES
NO
*2.10f
Fire service inlet (4 way) refer (NBC Part4-5.1.6.b)
YES
NO
*2.10g
Fire lift(546 Kg capacity)@1 for every 1200sq m floor area Refer (NBC-Part 4-appdx-C.1.5)
Name
Phone number(Landline/Mobile)
License no
signature
Builder
YES
NO
Architect
YES
NO
Structural Engineer
YES
NO
Electrical Contractor
YES
NO
Fire Safety Systems Contractor
YES
NO
Explanatory Notes
III
3a.1
"NBC"---National Building Code of India ( as amended in 2005 and) . " Part 3"/" Part 4", "Part 2" etc. refer to parts of NBC.
3a.2
I.E.R. refers to Indian electrical rules.
3a.3
S.P.30-1984 is the National Electrical Code.
3a.4
I.S. refers to Indian Standards
3b
NBC-Part 4-appdx-D, is mandatory for bldgs. 15 mts and above. However, may be referred to for other buildings. Also, depending on the degree of compliance with applicable rules or local conditions, as determined by the fire department
3c
Each of the rules is sufficient provided all others are followed. Hence, inadequate compliance with one rule may warrant enhanced stress on others, as consented to by fire department
3d
Brief descriptions are given for each item The referred rules give details
3e
Considering the safety scenario in most high-rise bldgs., the unreliability of power supply, and the high incidence of elec. shorts circuits, etc., resulting in fires, the manual and automatic fire-alarm are preferred for all high-rise bldgs. For the same reasons and because delays in fire reporting/ quenching is often causing avoidable loss of lives and property. Hence automatic sprinklers, which have proven cost effective, are preferred for such bldgs.
3f
In the pre construction design provisions and commitments can be evaluated but all columns cannot be filled in detail. In this case brief description with applicable I.S. can be given. However, in the post construction stage, specific details of installations, corrections in approved drawings to reflect "as-built" situations, and certificates etc, duly signed by technical persons, should be submitted and all columns filled up, to facilitate inspection, functional checks and issuance of final NOC required for occupancy certificate from Municipal authorities.
3g
NOC is valid for the particulars provided in the application. For any change of class of occupancy, fresh NOC for occupancy will be required. (NBC-Part 4-3.1.12 & 3.1.14 & NBC- Part 2 cl -13.2.f & B-4.2. Part 3-b).
3h 3i
Most of the fatalities, in fire incidents are due to a) Unrestrained and avoidable spreading of Smoke / fumes due to insufficient smoke Sealing/exhaust arrangements b) Smoke in escape route and in stairs make them Difficult to use. c) Inadequate aggregate width of stairs with insufficient ventilations. If smoke exclusion from exit stair case is not ensured, then larger aggregate width of stairs would be required to ensure evacuation of inmates of affected floors within two and half minutes stipulated in NBC Part 4-cl-8.4 Any critical delay in rescue by fire fighters because of insufficient access to the mandatory 6m-width access path compounds the problem due to obstructions (upto 4.5m height) like low balconies, support structures and fixtures and parking of vehicles. Therefore the rules related to 8 and 9 above call for strict compliance for preventing
3j
In each specific case, the fire department may stipulate additional measures, as being necessary for ensuring fire safety of building inmates and public (Section 12 of Telangana Fire Service Act, 1999)
3k
The architect and the owner of the building shall sign the checklist and plans.
3l
This checklist does not cover cinema occupancy (sub-occupancy type 01 & 02)
Form - 17 [See Rule 15(1)(d)] Undertaking on Rs. 100/- stamp paper format (To be typed on Rs. 100/- Stamp Paper) Undertaking
This letter of undertaking is executed by
..Infavour of the Director General, Fire and Emerge Services, BRKR Govt., Offices/Complex, Tank Bund Road, Hyderabad-500063.
We say that we are promoters and Developers Builders of the Multi storeyed building
We say that as stipulated by you we will provide all fire s< systems as per National Building Code and Multi-Storeyed Building Regulations, 1981 in the above Multi-Storeyed Building and prepare estimate of Rs towards the provision of all Fire Fighting System and submit the estimate in original along with the general information checklist/on fire safety measures for approval.
We undertake to incur an expenditure of Rs ............for providing Fire Safety arrangements as per details furnished in the above estimate.
We undertake to furnish Bank Guarantee for 15% of the estimated cost of fire safety systems as above in favour of Director General of Fire Services, obtained from any Nationalised Bank for a period years guaranteeing to provide all fire fighting systems as per National Bui Code and maintain them in good working condition round the clock.
We agree that the above Bank Guarantee can be invoked by Director General of Fire Services at any time in the event of non-provision or maintenance of fire fighting systems in our Multi-storeyed Building as per National Building Code or in the event of non-compliance of any of the safety measures suggested in the provisional No-Objection Certificate.
We also agree that the provisional No-Objection Certificate shall be issued by the Director General of fire services for the construction of Multi-storeyed Building only after furnishing the above bank guarantee by us.
We say that as stipulated by you we will undertake to impart training to 40% of the occupants and employees working at Building in fire prevention and fire fighting at Telangana Fire Service State Training School, Vattinagulapally, Hyderabad within 6 months from the date of occupation.
We undertake to maintain and keep the fire fighting equipment installed at Building............
good working condition at all times by regularly servicing and replacing the obsolete equipment.
Place:
Signature ofthe Builder/Promoter/Developer
Date:
Name:
Designation:
Address for Correspondence Contact
Telephone number.
Form No. 18
[See Rule 15(l)(f)] Government of Telangana Fire and Emergency Services Department
From
To
Rc. No ,.........
Date..................
Sir,
Sub: - Fire and Emergency Services Department - Construction of Multi Storeyed Building by …………Issue of No Objection Certificate -Reg.
Ref:- 1) Application of M/s .....................with e-SevaUnique I.D. No……
Report of the Multi-Storeyed Building Inspection Committee, Hyderabad Rc. No
Judgment dated 28.9.2006 of the Hon'ble High Court of A.P. in W.P. M.P. No. 21991 of 2006 in W.P. No. 26365 of 2005.
Vide reference cited (3) (copy enclosed), the Hon'ble High Court has directed that:
"Since the Department has carried out necessary inspection and has found nothing objectionable, we give liberty to the concerned authority to issue no objection certificate to the applicant subject to the condition that if the applicant makes any deviation from the sanctioned plan, then the competent authority shall be entitled to demolish the entire building irrespective of the stage of construction.
The department has in last more than six months rigorously ensured total adherence to the norms prescribed and the relevant statutory provisions made for taking fire safety measures, we deem it proper to modify order dated 21.3.2006 and direct that the competent authority shall be free to consider and decide the applications made in further for grant of No Objection Certificate under the A.P. Fire Service Act, 1999 after clearance by the Multi-store Building Inspection Committee."
The Multi-Storeyed Building Inspection Committee, Telangana Fire Services Department vide reference cited (2) has recommended for the issuance of No Objection Certificate to the proposed Multi-Storeyed Building with …….. with a height of for Occupancy being constructed by M/s……
In pursuance of the orders of the Hon'ble High Court cited above, the No Objection Certificate is issued to the proposed Multi-Storeyed Building block with . ……with a height of - meters for -Occupancy being constructed M/s ………. as per section
13(1) of Telangana Fire Service act,1999 and building plans are forwarded herewith after countersigning the same for your approval.
The Builder may be informed of the following Act/Rules/Regulations
Telangana Fire Service Act, 1999:
As per Section 31 of "whoever wilfully contravenes any provisions of this Act or the rules made thereunder or fails to comply with any requisition lawfully made upon him under any provisions of this Act shall, without prejudice to any other action taken against him under Section 22 be punishable with imprisonment for a term which may extend to three months or with fine which may extend to twenty five thousand rupees or with both; and where the offence is a continuing one, with a further fine which may extend to three thousand rupees for every day during which such offence continues after the conviction for the first such offence.
Show cause notice to be served on the Defaulter
Whereas, it is necessary in public interest and safety, I hereby direct you, Sri/Smt....../M/s....(Firm/Company/Business/Owner/Occupier) possessor of Fire Service Licence No....
dated......that you have violated the conditions mentioned therein by not maintaining the fire fighting system in satisfactory working condition/defective/having not provided the following thereby endangering lives and properties of the inmates and public in and around your premises.
Take notice hereby, that you are directed to rectify the above defects and re-set the fire protection system ensuring the safety within 30 days from the date of receipt of this notice lest, Fire Service Licence issued to you shall be cancelled/your renewal application refused besides action taken against you to prosecute in the Court of Law under Section 31 of Telangana Fire Service Act, 1999.
You are directed to acknowledge receipt of this notice on its duplicate.
Signature of the Authorized Officer
Sri ....
......
Form - 15
[See Rule 37(2)]
Telangana Fire and Emergency Operational Services
Certificate of Appointment for members of Auxiliary Fire Service
| Affix photograph here |
This is to certify that Sri .... has been appointed as a member of Auxiliary Fire Service in the rank of.... on ....
under ....Section 8 of the Telangana Fire Service Act and is vested with the powers, functions and privileges of a member of service as given in Rule 3 of the Telangana Fire and Emergency Operational and Levy of Fee Rules.
(Issuing Authority)
(Director General of Fire Services)/
(Regional Fire Officer)/
(Divisional Fire Officer).
Form No. - 16
[See Rule 15(1)(a)]
Check list for issuance of No Objection Certificate for High Rise
Form - 12 [See Rule 26(2)]
Notice for violation of Fire Prevention and Fire Safety Measures
I,....................empowered by Section 21 of Telangana Fire Service Act, 1999 and Rule 26 of Telangana Fire and Emergency Operations and Levy of Fee Rules, 2006 on the basis of inspection conducted by me on ........do hereby call upon you to undertake the following fire prevention and fire safety measures in building/premises No....
................
......
......
You have violated the conditions of Fire Service Licence and thereby endangering lives and property of the inmates and public in and around your premises.
Take notice hereby that you are directed to undertake the above fire safety and fire prevention measures ensuring the safety within 15/30 days from the date of receipt of this notice, failing which your Fire Service Licence shall be cancelled/your renewal application refused besides action will be taken as per the Rules.
Date:
Signature of the Inspecting Officer
Place:
Form13
[See Rule 29(5) (a)]
Notice to obtain Fire Service Licence
Take notice that you are running trade.... located at premises No...... without obtaining Licence from the Telangana Fire Services Department under Section 30 of Telangana Fire Service Act,1999.
Hence, you are served this Notice to obtain licence within 30 days from the date of
receipt of this notice, failing which statutory action will be taken against you as per rules.
Signature of the Authorized Officer
Place:
Smt./Sri ....
Form - 14
[See Rule 29(5)(b)]
Number of floors _Number of Basements _Number of Stilts /Ground floor _
Number of floors _Number of Basements _Number of Stilts /Ground floor _
*1.14.2.1
Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _
Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _
Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _
Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _
Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _
Capacity (aggregate width) of exits shall be based on occupant load (in the affected floor(s) and occupants that can be safely evacuated per 50 cms of exit, which is: 25/50/75 for stairs/ramp /doors, respectively, for residential educational or institutional bldgs. Corresponding figures are 50/ 60/ 75 for business& mercantile bldgs., for assembly occupancy 40/50/60, stairs/doors/ramps respectively(NBC- Part 4-4.3/ 4.4) (Aggregate stairs width) _
1.14.2.2
Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC)
Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC)
Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC)
Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC)
Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC)
Whether horizontal exits are provided ____(Provided/Not Provided)Note:- When horizontal exit is provided in buildings of mercantile, storage, industrial, business and assembly occupancies, the capacity per storey per unit width of exit of stair ways in table 21 may be increased by 50 percent and in buildings of institutional occupancy it may be increased by 100 percent (4.4.3 Part 4 NBC)
1.14.3
Floor
Area in Sq. Mtrs.
Classification of Occupancy:
No. Of Occupants as declared by the Builder:
No. Of occupants based on Table 20 i.e floor area divided by occupant load:
Total Aggregate width of Stair-Case in Mtrs. (as declared by the Builder):
1.14.3
Basement -1
1.14.3
Basement -2 Stilt 1/ Ground Floor
Stilt 2
Floor1
Floor2
Floor3
Floor4
Floor5
Floor6
Floor7
Floor8
Floor9
Floor10
1.15
Refuge area:
Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs
Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs
Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs
Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs
Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs
Refuge area (NBC- 4-4.12.3 & Appendix D-1.11) ____ sq mtrs
*1.16
Width of the road to which the building abuts and whether it is hard surfaced and motorable:
The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2
The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2
The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2
The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2
The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2
The premises is abutting ____ no of Roads. For Minimum width of abutting street refer (NBC-Part 3-4.6.a; 4.8; part 4-7.4.1.a). (Note: The Abutting Road width should be minimum 12 mtrs.) Specify Abutting Street Details: Abutting Street Name Abutting Street Width in mtrs. Side Abutting Street 1 Abutting Street 2
*1.17
Entrances (Minimum width should be 4.5 mtrs. and head room clearance should be minimum 5.0 mtrs.)
Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs.
Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs.
Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs.
Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs.
Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs.
Proposed to provide ____ number of entrance/exit. Specify: Entrance/Exit Details Entrance width in mtrs. Abutting Road Width Side Entrance 1 Entrance 2 Head room clearance ______ mtrs.
*1.18
Car parking
Car Parking Details: Basement/Stilt/Ground Floor No Of Cars
Car Parking Details: Basement/Stilt/Ground Floor No Of Cars
Car Parking Details: Basement/Stilt/Ground Floor No Of Cars
Car Parking Details: Basement/Stilt/Ground Floor No Of Cars
Car Parking Details: Basement/Stilt/Ground Floor No Of Cars
Car Parking Details: Basement/Stilt/Ground Floor No Of Cars
*1.20.3.1
Staircase 1Staircase 2Staircase 3Staircase 4Staircase 5(Note:- External staircase shall terminate at Ground/Stilt floor only, it should not extend to the basement. Minimum width should be 1.25 Mtrs.)
*1.20.3.2
Width of the Treads ____ cm
*1.20.3.3
Height of the riser ____ cm
*1.20.3.4
Number of riser ____ per flight
*1.20.3.5
Height of the hand rails ____ mtr. (should be 1 mtr.).
*1.20.3.6
The gap between two verticals cm (should not exceed 15 cm)
*1.20.3.7
Head room clearance mtr.
1.21
Lifts:
1.21.1
Number of Passenger liftsPassenger Lift Details Capacity (kgs)Passenger Lift 1Passenger Lift 2
1.21.2
Number of Service liftsService Lift Details: Capacity (kgs)Service Lift 1Service Lift 2
1.22
Generator
Number of Electrical GeneratorsGenerator Details: Capacity (kva)Generator 1Generator 2Note:- Electrical generator with auto start and auto changeover from normal to emergency source to supply power to staircase and corridor lighting circuits, fire lifts, the standby fire pump, pressurization fans and blowers, smoke extraction and damper systems in case of failure of normal electric supply.
*1.23
Minimum fixed fire fighting installations
Whether minimum fixed fire fighting installations as prescribed in table 23 of NBC-Part 4 are provided (NBC -4 Appdx -d is also applicable)
1.23.1
Proposed to provide number of Manual Call Points in the entire building.
1.23.2
Proposed to provide number of Smoke Detectors, number Of Heat detectors, number of Beam Detectors in the entire building.(Please refer IS 2189:1999)
1.23.3
Proposed to provide Detection Control Panel in floor.
1.23.4
Proposed to provide number of automatic sprinklers in the entire building.(Please refer IS 15105:2002)
1.23.5
Proposed to provide number of Hose Reels in the entire building.
1.23.6
Proposed to provide __number of Wet Risers/Wet Riser cum Down comers.
1.23.7
Proposed to provide __number of Yard Hydrants.
*1.23.8(a)
Proposed to provide __ number of Underground Static Water tank/tanks, totally __ltrs. capacity.Underground Static water Tank Details: Ltrs.Underground Static water Tank 1Underground Static water Tank 2
1.23.8(b)
Mention Nearest Water source ____(River/Lake/Pond/Well/ Municipal Water Works)
*1.23.9
Proposed to provide __number of Terrace tank/tanks, totally __ltrs. Capacity.Terrace Tank Details Ltrs.Terrace Tank 1Terrace Tank 2
Electrical Pump for Sprinkler system Details: ltrs./min. capacity.Electrical Pump for Sprinkler System 1Electrical Pump for Sprinkler System 2
1.23.10.5
Booster Pump Details: ltrs./min. capacity.
NO
*2.3.7
Occupancy of all parts/ floors of bldg. (NBC- Part 2-12.2.5b; 13.2.f; Part 4-3.1.12/3.1.14 & 4.3)
YES
NO
2.3.8
For filling item 2.3.8.1-2.3.8.4, please refer to (NBC- Part 2-12.2.5.1.j/n;-Part 4-3.4.11/12;-C1.6/7; 1.17)
2.3.8.1
Details of : air-conditioning & dampers
YES
NO
NA
2.3.8.2
Details of : mechanical ventilation & smoke exhaust Systems
YES
NO
NA
2.3.8.3
Details of : vents for smoke to minimize their spread
YES
NO
NA
2.3.8.4
Details of : Vents which should be minimum 2.5% of floor area of Basement
YES
NO
NA
2.3.9
For filling item 2.3.9.1-2.3.9.2, please refer to (NBC- Part 2-12.2.5.1.d/e/m; Part 4-3.4/4; C-1.5/16; IS-1646;I.E.R.)
*2.3. 9.1
Location of elec. sub-station, transformer , generator, fire-lift
YES
NO
*2.3. 9.2
Location of smoke-stops in lobby/ floors
YES
NO
2.3.10
For filling item 2.3.10.1-2.3.10.4, please refer to (NBC- Part 2-12.2.5.p/q/r/s;-Part 4.5.1.2)
*2.3.10.1
Underground static water storage tank, terrace tank and fire pumps
YES
NO
*2.3.10.2
Detection and fire alarm systems
YES
NO
*2.3.10.3
Hose-reels, wet-riser/wet riser cum Down comer (minimum one wet riser for every 1000 sq.m. covered area)
YES
NO
*2.3.10.4
Automatic Sprinklers (basement area >200 sq.m. automatic sprinklers should be provided)
YES
NO
*2.3.11
Details of motorable access to & around bldg. and turning radius at bldg. corners. (NBC- Part 2-12.2.5.1.a;- Part 3-4.6/7)
YES
NO
*2.3.12
Vehicular parking spaces (NBC- Part 2-12.2.51.g , Part 3-10/appdx.B)
YES
NO
2.3.13
For filling item 2.3.13.1-2.3.13.3, please refer to (NBC- Part 2-12.2.5.1.b/k; Part 3-12.9.3.f; Part 2-8.3 to 13)(Note NBC-Part 4-4.2.9; 4.2.10.m; C.6.2; for stairs from upper floors to basement. For corresponding rules for lifts, see NBC-Part 4-appdx-C1.5.h/j )
*2.3.13.1
Size(widths) of exit stair cases
YES
NO
*2.3.13.2
Size(widths) of balcony approach, corridors
YES
NO
*2.3.13.3
Size(widths) of ventilated lobby approach
YES
NO
2.3.14
Compartmentation (if any), show typical detail of fire-resistant doors/stops (NBC- 4-4.7, 3.4.8, 3.4.9; C-9)
YES
NO
NA
2.3.15
Site plan duly marking open spaces on all sides from the building line to boundary of the premises
YES
NO
NA
2.4
Type of Construction (NBC-Part 4-3.3)
Type of Construction (NBC-Part 4-3.3)
*2.4.1
Construction to be type 1, including for ,external walls, load bearing elements, roof, stairs, lifts ,exit routes corridors.( NBC-Part 4-3.3, 3.4.7; IS-1642)
YES
NO
*2.4.2
Specifications for all fire safety items like fire resistant doors used as "fire Cut-offs" or " fire-breaks", or for stairs/lifts, to be furnished (NBC-Part 4-3.4.8.1/3/9)
YES
NO
*2.4.3
Finishing material used for interior surfaces and decor not to generate toxic smoke/fumes (NBC- 3.4.15; IS 12777 &
YES
NO
Illumination required to ensure safe travel
YES
NO
2.7
2.7a
Internal Staircase
2.7a.1
For (2.7.a.1.1-2.7.a.1.4) ( Refer NBC- Part 4-4.9.6/7/8)
*2.7a.1.1
Minimum width 1.5 mts.. for other than Assembly buildings (For Assembly and Hospital buildings minimum width is 2.0 meters)( Net width of stairs, available between hand rails important)
YES
NO
*2.7a.1.2
Tread 25/30 cms. for residential/other than assembly
YES
NO
*2.7.a.1.3
Riser max 15 cms ht.
YES
NO
*2.7a.1.4
No. of risers not more than 15 Nos. per flight
YES
NO
*2.7a.1.5
Construction should be with non-combustibles material.(NBC- Part 4- 4.9.1)
YES
NO
*2.7a.2
To be a self contained unit with at least one external wall and be completely enclosed. (NBC- Part 4- 4.9.2)
YES
NO
*2.7a.3
Shall not be around lift(NBC-Part 4-4.9.3)
YES
NO
*2.7a.4
Hand rails to be at at 100 cms. height (NBC- Part 4- 4.9.9)
YES
NO
*2.7a.5
To be designed such that the No. of people in between floor landings, is not less than those on each floor. (NBC- Part 4-4.9.10)
YES
NO
*2.7a.6
To contain no electrical shafts/AC ducts or gas pipes. (NBC-Part 4-4.9.4/10f)
YES
NO
*2.7a.7
Access to stairs shall be through two hr. rated fire/smoke door (NBC-Part 4-4.9.10.b)
YES
NO
2.7b
External Stairs
*2.7b.1
Shall be directly connected to ground. (NBC- Part 4-4.11.2)
YES
NO
*2.7b.2
Minimum width 1.25 meters
YES
NO
*2.7b.3
Entrance to be separate and remote from internal stairs.(NBC-Part 4-4.11.3)
YES
NO
YES
NO
*2.10a.10
Openable windows, on external walls or on fully glazed facades, to have locks which can be opened by fire-man's axe to enable quick access for rescue of inmates, and for fire-fighting. (NBC-Part 4-3.4.16,C.1.7). (Note - Accessibility of fire men into higher floors is important)
YES
NO
2.10b
Air Conditioning/ Ventilation
2.10b.1
To be designed to minimize spreading of fire smoke & fumes from one fire area/floor to another or to escape/exit path,staircases, etc. (NBC- Part 4-3.4.11 & C1.17; Part 3-sec.-1/3)
YES
NO
NA
*2.10b.2
In case of fire, or smoke at A.C's outlet, Automatic dampers to close, to stop spreading of smoke
YES
NO
*2.10b.3
In case of fire, stop fans, unless these are arranged to remove smoke from fire area.(NBC-Part 4-3.4.11,2)
YES
NO
*2.10b.4
From safety point of view, separate air handling systems for various floors are preferred, to minimize hazard of smoke spreading. Refer (NBC-Part 4-3.4.11.4)
YES
NO
2.10c
Smoke Venting Note -It is well established that far greater lives are lost due to smoke (more so, if exits are deficient), than due to fire-burns refer (NBC-Part 4-3.4.1/12,4.2.9,C1.6 )
*2.10c.1
Automatic smoke vents, with area min.3.3% of floor area, in assembly areas and balconies, shall be installed. Refer (NBC-Part 4-3.4.6.4.2/6,4.4,6.4.6.11)
YES
NO
*2.10c.2
The above, is natural draft smoke venting, opened by smoke sensitive device, automatically. To substitute this with powered exhausters, dept.'s permission is reqd. Refer (NBC-Part 4-3.4,6.4.4/6.4.5)
YES
NO
2.10d
Basements (Please refer 12.9.3 of Part 3 NBC and C 1.6 of Part 4 NBC)
2.10d.1
Basements, to be separately ventilated with grills etc.having 2.5% area of floor. Alternately, air inlet& smoke outlet ducts at floor & ceiling level resp. be provided refer (NBC-Part 4- C.1.6.1)
YES
NO
NA
2.10d.2
Mechanical extractors with 30 change/hr. in case of fire fed by alternate power also reqd. for lower basement, if any. Refer (NBC-Part 4-C.1.6.4)
YES
NO
NA
2.10d.3
Smoke from basement fire shall in no case ingress into any exit path/stairs serving upper floors. Refer (NBC-Part 4- C1.6.6)
YES
NO
NA
2.10d.4
Use of LPG/Pressure. stove in basements is prohibited, while allowed in other areas 4 hr, fire- resistant enclosures. Refer (NBC- Part 3-12.9; Part 4-C1.6.5)
YES
NO
NA
2.10.d.5
Every basement shall be in every part at least 2.4 m in height from the floor to the underside of the roof slab or ceiling.
YES
NO
NA
2.10.d.6
Adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to byelaws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air-conditioning systems etc.
YES
NO
NA
2.10.d.7
The minimum height of the ceiling of any basement shall be 0.9 m and the maximum 1.2 m above the average surrounding ground level
YES
NO
NA
2.10.d.8
Adequate arrangements shall be made such that surface drainage does not enter the basement
YES
NO
NA
2.10.d.9
The walls and floors of the basement shall be watertight and be so designed that the effects of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given
YES
NO
NA
2.10.d.10
The access to the basement shall be separate from the main and alternative staircase providing access and exit from higher floors. Where the staircase is continuous in the case of buildings served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors. Open ramps shall be permitted if they are constructed within the building line subject to the provision of 2.10.d.8. Note: - The exit requirements in basements shall comply with
YES
NO
NA
YES
NO
2.11
Special Hazards
Special Hazards
*2.11.1
Rooms with refrigeration equipment/transformer not to be adjacent to each other and should be vented separately to outer air.(NBC-Part 4-6.4.6.5)
YES
NO
*2.11.2
All rooms/areas storing combustible material/equipment/etc. be effectively cut off from exits/assembly areas.(NBC-Part 46.4.6.6)
YES
NO
*2.11.3
Whether minimum fixed fire fighting installations as prescribed in table 23 of NBC-Part 4 are provided( NBC -Part 4 appdx -d is also applicable)1) Proposed to provide emergency lighting with minimum 2 hrs battery backup in the escape route.
YES
NO
*2.11.3
2 Proposed to provide Auto glow signages in all floors.
YES
NO
*2.11.3
3) Proposed to provide Public Address System
YES
NO
2.12
2.12
Miscellaneous
*2.12.1
For building 15m and above, NBC-Part 4, appdx-C is applicable
YES
NO
*2.12.2
One Fire lift with capacity of not less than 545 kg. (8 persons lift) for every 1200 sq mtrs of floor area shall be provided (NBC-Part 4-C.1.5)
YES
NO
*2.12.3
All floors to be compartmented into 750 sq. mtrs. area through 2hr rated fire separation walls (NBC- Part 4 -C.1.8)
YES
NO
*2.12.4
Basement ventilation and staircases shall be such that smoke cannot travel to upper floors
YES
NO
2.12.5.(a)
For Buildings above 60 mtrs height, whether helipad arrangement is made (cl C.10 of annexure C Part 4 NBC, 2005)
YES
NO
NA
2.12.5.(b)
For Buildings above 60 mtrs height, Whether the additional Emergency plan of action including provision and maintenance of Hydraulic platform with capacity to have an access up to the terrace of the building round the clock with officer and crew duly signed by a qualified fire Engineer is enclosed?
YES
NO
NA
2.12.5.(c)
For Buildings above 60 mtrs height, Whether Fire fighting shafts as per BS 5588 of 1986 are proposed and earmarked in the plans.
YES
NO
NA
*2.12.6
Whether compartmentation of upper floors i.e. one compartment for maximum of 1125 sq. mtrs floor area is proposed to be done to confine the fire/smoke to the area where fire incident has occurred (Cl C.9 Annexure C , Part 4, NBC, 2005
YES
NO
*2.12.7
Whether smoke management is strictly ensured, so that exit route is free from smoke logging in case of fire.(Cl 3.4.8, 3.4.9, 3.4.12,4.2.9,4.10 Part 4 NBC, 2005
YES
NO
2.13
Fire pumps (Refer Table 23 of Part 4 of NBC, 2005)
Fire pumps (Refer Table 23 of Part 4 of NBC, 2005)
*2.13.1
Whether estimates for Fire Safety System (certified by the architect) submitted?
YES
NO
*2.13.2
Whether 15% of the estimates of Fire Safety System as Bank Guarantee is submitted?
YES
NO
*2.13.3
Whether challan copy submitted ?
YES
NO
*2.13.4
Whether Undertaking on Rs 100/- Stamp paper submitted ?
YES
NO
*2.14
Provide name, address, licensed no., signature of technical staff
Provide name, address, licensed no., signature of technical staff