(Refer Regulation No. 2.16)
Before Issuing Building Use Permission, Competent Authority shall check that:
1.Tree plantation required under these Regulations are planted on site or ensure this by taking suitable deposits as decided from time to time for specific period by the Competent Authority.
2.Parking space is properly paved & the lay‐out of parking space is provided as per the
approved plans. Sign‐ boards indicating the entrance, exit and location of parking spaces for different types of vehicles shall be permanently erected and maintained at the prominent place in every Building‐unit.
3.Certificate of lift Inspector (Government of Gujarat) has been procured & submitted by the
owner, regarding satisfactory erection of Lift.
a.Proper arrangements are made for regular maintenance of lift as provided in NBC and in these regulations
b. The Certificate of Competent Authority and or fire department for completion and or fire requirements as provided in these regulations has been procured and submitted by the owner.
4.Proper arrangements are made for regular maintenance of fire protection services as provided in NBC and in these regulations
5.There shall be a percolating well / pit in a Building‐unit having area more than 1500 sq.mt.
6.The Concerned Authority issuing occupancy certificate before doing so shall consult concerned designated Authority to inspect the building and issue a certificate that necessary requirements for the fire protection under these regulations as per regulation No.18.2 have been fulfilled and if not so, the applicant shall be asked to carry out necessary additions, alterations or rectification to the satisfaction of the designated Authority before issuing occupancy certificate.