(5) Industrial plots: For plot within industrial use zones as per Master Plan-
| Sl no | Type | Plot size (in sqm) | Maximum F.A.R | Maximum Coverage (in %) | Maximum Height (in m) | Minimum Setbacks (in m) | ||
| Front | Sides | Rear | ||||||
| 1 | Standalone factory | 300 (min.) - 500 | 2.0 | 75 | 15 | 1.2 | 0.9 | 0.9 |
| 501 - 1000 | 2.0 | 75 | 15 | 1.5 | 1.2 | 1.2 | ||
| 1001- above | 2.0 | 75 | 15 | 2.0 | 1.5 | 1.5 | ||
| 2 | Flatted group industry and service center | 1000 (min.) | 2.0 | 70 | 19 | 1.5 | 3.0 | 2.5 |
(6) Special provisions for Commercial buildings: For plot within commercial use zones as per Master Plan with 100% commercial use-
| Sl no | Type | Plot size (in sqm) | Maximum F.A.R | Maximum Coverage (in %) | Maximum Height (in m) | Minimum Setbacks (in m) | ||
| Front | Sides | Rear | ||||||
| 1 | Commercial Building | 300 (min.) | 5.0 | 75 | 21 | 1.2 | 1.2 | 1.2 |
Provided that when an entire ϐloor is used for parking such ϐloor shall not be counted for calculating F.A.R and height limit subject to the condition that the total height shall not exceed 24m.
Provided further that in the case of Commercial Buildings in new Central Business District (CBD) and Transit Oriented Development (TOD) corridors delineated by Master Plan an addition of +2 F.A.R is permissible for plots of 500sqm and above on the merit of the speciϐic site conditions.